c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
1,205 kWh
134 cooling + 1,071 heating
Estimated running cost
$398 / year
$33 / month Β· $3,977 over 10 years
Capacity
2 kW cooling
2.5 kW heating

45% more electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 11% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 86% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Toshiba RAS-07E2AVG-A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,205$398$3,977
Mixed zone 577$190$1,904
Hot zone 657$217$2,168

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
TCL TAC-06CSHD/*IH1.8 kW heating1.8 kW cooling630 kWh/yr3.5$208
TCL TAC-06CHSD/VFIH1.8 kW heating1.8 kW cooling630 kWh/yr3.5$208
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237

Heat pumps similar to the Toshiba RAS-07E2AVG-A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRG020N8/42QRG020N82.2 kW heating2 kW cooling734 kWh/yr5$242
Mitsubishi Heavy Industries SRC20ZSXA-W / SRK20ZSXA-W2.7 kW heating2 kW cooling749 kWh/yr4.5$247
Mitsubishi Heavy Industries SRC20ZSXA-W/SRK20ZSXA-WF2.7 kW heating2 kW cooling751 kWh/yr4.5$248
Kaden KSI062.3 kW heating2 kW cooling718 kWh/yr5.5$237
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling734 kWh/yr5$242
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237

Compare RAS-07E2AVG-A/RAS-07E2KVG-A with another model

Toshiba RAS-07E2AVG-A specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.00 kW
Cooling power input
0.53 kW
Rated heating capacity (7 Β°C)
2.50 kW
Heating power input
0.64 kW
EER, full load (tested)
3.77
COP, full load (tested)
3.94
Rated AEER
3.75
Rated ACOP
3.89
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Toshiba RAS-07E2AVG-A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––308334
Coldresidential2.51.51341,071
Mixedcommercial––382161
Mixedresidential2.52.0206371
Hotcommercial––82732
Hotresidential2.52.560651
Part-load test points (18 values)
h__h1_min_cap_power_rated
200 W
h__h2_ext_cap_power_rated
820 W
c__t1_half_cap_power_rated
260 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
270 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
900 W
h__h2_ext_cap_heat_cap_rated
1850 W
h__h1_half_cap_heat_cap_rated
1250 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9658
GEMS registration id
174942
Status
approved, available (self-reported)
Registration expires
11 February 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: toshiba-aircon.in.th. How the derived figures are calculated.