c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,308 kWh
160 cooling + 1,148 heating
Estimated running cost
$432 / year
$36 / month Β· $4,316 over 10 years
Capacity
3.5 kW cooling
3.7 kW heating

6% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 71% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Toshiba running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,308$432$4,316
Mixed zone 685$226$2,261
Hot zone 806$266$2,660

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Toshiba

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MUZ-AP35VG2/MSZ-AP35VGKD23.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Mitsubishi Electric MUZ-AP35VGD2/MSZ-AP35VGKD23.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Rinnai HONRPX35/HINRPX35M3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Midea MFEZ35VA-W/MFEZ35VA-N3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Compare RAS-13ZAVSG-A / RAS-13ZKVSG-A with another model

Toshiba specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
0.81 kW
Rated heating capacity (7 Β°C)
3.70 kW
Heating power input
0.82 kW
EER, full load (tested)
4.25
COP, full load (tested)
4.61
Rated AEER
4.31
Rated ACOP
4.50
Standby power (PIA)
0.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
58 dB(A)
Outdoor sound power
62 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Toshiba zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––303375
Coldresidential4.52.51601,148
Mixedcommercial––409199
Mixedresidential4.03.0253432
Hotcommercial––94641
Hotresidential4.53.574264
Part-load test points (25 values)
c__t1_min_cap_power_rated
220 W
h__h1_min_cap_power_rated
190 W
h__h2_ext_cap_power_rated
1370 W
c__t1_half_cap_power_rated
350 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
330 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
900 W
h__h2_ext_cap_heat_cap_rated
3900 W
h__h1_half_cap_heat_cap_rated
1850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
180 W
c__t1_min_cap_cooling_cap_rated
800 W
c__low_temp_full_cap_power_rated
740.34 W
c__low_temp_half_cap_power_rated
280 W
c__t1_half_cap_cooling_cap_rated
1750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1070 W
c__low_temp_full_cap_cooling_cap_rated
3769.5 W
c__low_temp_half_cap_cooling_cap_rated
1950 W

New Zealand E3 registration details

Registration number
AAC8493
GEMS registration id
164830
Status
approved, available (self-reported)
Registration expires
13 October 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.