c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
2,324 kWh
254 cooling + 2,070 heating
Estimated running cost
$767 / year
$64 / month Β· $7,669 over 10 years
Capacity
4.2 kW cooling
5.4 kW heating

67% more electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 1% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 71% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Toshiba RAS-16E2AVG-A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,324$767$7,669
Mixed zone 1,127$372$3,719
Hot zone 1,294$427$4,270

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hisense HAWU12KR3.9 kW heating3.7 kW cooling1,332 kWh/yr6$440
Hisense HAWH12KR3.9 kW heating3.7 kW cooling1,360 kWh/yr5$449
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Toshiba RAS-13U2AVSG-NZ / RAS-13U2FVG-NZ4.2 kW heating4 kW cooling1,756 kWh/yr4$579

Heat pumps similar to the Toshiba RAS-16E2AVG-A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic CU-Z42DKR / CS-Z42DKRW5 kW heating4.2 kW cooling1,969 kWh/yr3.5$650
Mitsubishi Heavy Industries SRC42ZTA-W* / SRK42ZTA-WF*5.4 kW heating4.2 kW cooling1,950 kWh/yr4.5$644
Mitsubishi Heavy Industries SRC42ZTA-W/SRK42ZTA-WF5.4 kW heating4.2 kW cooling1,950 kWh/yr4.5$644
Panasonic CU-*Z42DKR / CS-*Z42DKRW5 kW heating4.2 kW cooling1,969 kWh/yr3.5$650
Mitsubishi Electric MUZ-AP42VGD2/MSZ-AP42VGD5.4 kW heating4.2 kW cooling2,017 kWh/yr4$666
Mitsubishi Electric MUZ-AP42VG2/MSZ-AP42VGD5.4 kW heating4.2 kW cooling2,017 kWh/yr4$666
Fujitsu AOTH14KNCA/ASTH14KNCA4.7 kW heating4.2 kW cooling1,822 kWh/yr4$601

Other Toshiba models of similar capacity

ModelStarsEst. cost / yrCompare
Toshiba RAS-16ZAVSG-A / RAS-16ZKVSG-A5.4 kW heating4.2 kW cooling2,099 kWh/yr4$693

Compare RAS-16E2AVG-A/RAS-16E2KV2G-A with another model

Toshiba RAS-16E2AVG-A specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.20 kW
Cooling power input
1.30 kW
Rated heating capacity (7 Β°C)
5.40 kW
Heating power input
1.43 kW
EER, full load (tested)
3.25
COP, full load (tested)
3.54
Rated AEER
3.22
Rated ACOP
3.77
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62 dB(A)
Outdoor sound power
67 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Toshiba RAS-16E2AVG-A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––562609
Coldresidential3.01.52542,070
Mixedcommercial––713301
Mixedresidential2.52.5404723
Hotcommercial––1,60858
Hotresidential3.03.01,20094
Part-load test points (18 values)
h__h1_min_cap_power_rated
250 W
h__h2_ext_cap_power_rated
1560 W
c__t1_half_cap_power_rated
450 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
550 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1300 W
h__h2_ext_cap_heat_cap_rated
4200 W
h__h1_half_cap_heat_cap_rated
2700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2100 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9659
GEMS registration id
174943
Status
approved, available (self-reported)
Registration expires
25 February 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: toshiba-aircon.in.th. How the derived figures are calculated.