New Zealand Β· costs in NZD

Cooling only split system air conditioner, wall hung
Toshiba RAS-24E2ACVG-A/RAS-24E2KCVG-A Heat Pump
Toshiba RAS-24E2ACVG-A/RAS-24E2KCVG-A is a 6 kW cooling only split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10248).
- Energy rating (cooling)
- 3.5
- Annual electricity use
- 308 kWh
- Estimated running cost
- $102 / year
- $8 / month Β· $1,016 over 10 years
- Capacity
- 6 kW cooling
7% more electricity than the median of 8 comparable 6 kW cooling only split system registrations (288 kWh a year) in the cold zone. Uses less than 25% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 97% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Toshiba running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 308 | $102 | $1,016 |
| Mixed zone | 496 | $164 | $1,637 |
| Hot zone | 1,474 | $486 | $4,864 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling244 kWh/yr | 4.5 | $81 | |
| Mitsubishi Electric MUY-GW60VFD/MSY-GW60VFD26 kW cooling275 kWh/yr | 4 | $91 | |
| Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD26 kW cooling275 kWh/yr | 4 | $91 | |
| Daikin RKM60QVMA / FTKM60QVMA6 kW cooling279 kWh/yr | 4 | $92 | |
| Hitachi RAC-DJ60PCAT/RAK-DJ60PCAT6 kW cooling280 kWh/yr | 4 | $92 |
Heat pumps similar to the Toshiba
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD6 kW cooling275 kWh/yr | 4 | $91 | |
| Daikin RKM60Q2VMA / FTKM60Q2VMA6 kW cooling281 kWh/yr | 4 | $93 | |
| Hitachi RAC-DJ60PCAT/RAK-DJ60PCAT6 kW cooling280 kWh/yr | 4 | $92 | |
| Mitsubishi Electric MUY-GW60VFD/MSY-GW60VFD26 kW cooling275 kWh/yr | 4 | $91 | |
| Daikin RKM60QVMA / FTKM60QVMA6 kW cooling279 kWh/yr | 4 | $92 |
Other Toshiba models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling244 kWh/yr | 4.5 | $81 |
Compare RAS-24E2ACVG-A/RAS-24E2KCVG-A with another model
Toshiba specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.70 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.52
- COP, full load (tested)
- β
- Rated AEER
- 3.52
- Rated ACOP
- β
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 58 dB(A)
- Outdoor sound power
- 63 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Toshiba zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 673 | β |
| Coldresidential | residential | 3.5 | β | 308 | β |
| Mixedcommercial | commercial | β | β | 861 | β |
| Mixedresidential | residential | 3.5 | β | 496 | β |
| Hotcommercial | commercial | β | β | 1,962 | β |
| Hotresidential | residential | 3.5 | β | 1,474 | β |
Part-load test points (5 values)
- c__t1_half_cap_power_rated
- 530 W
- c__t1_have_min_cap_results
- No
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- No
New Zealand E3 registration details
- Registration number
- AAC10248
- GEMS registration id
- 180165
- Status
- approved, available (self-reported)
- Registration expires
- 13 September 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: toshiba-aircon.in.th. How the derived figures are calculated.