c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,414 kWh
1,283 cooling + 2,131 heating
Estimated running cost
$1,092 / year
$91 / month Β· $10,925 over 10 years
Capacity
13 kW cooling
15 kW heating

7% more electricity than the median of 140 comparable 12.5 kW reverse cycle ducted split system registrations (3,178 kWh a year) in the mixed zone. Uses less than 20% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 30% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air CRS13AS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,566$2,101$21,011
Mixed zone 3,414$1,092$10,925
Hot zone 4,084$1,307$13,069

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the Actron Air CRS13AS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U140S2SP5FA / AD140S2SM7FA15 kW heating13 kW cooling3,854 kWh/yr2$1,233
Hisense AUW-125U4RH1/AUD-125UX4RSH115.5 kW heating13 kW cooling3,223 kWh/yr3$1,031
Fujitsu AOTH54KBTA/ARTH54KMTAP15 kW heating13 kW cooling3,527 kWh/yr2.5$1,129
Fujitsu AOTG54LBTB/ARTG54LHTDP16 kW heating13 kW cooling3,665 kWh/yr2.5$1,173
Kaden KD4215 kW heating13 kW cooling3,551 kWh/yr2$1,136
Temperzone OSAT 130RLSFH / ISDT 130LY15.5 kW heating13 kW cooling3,354 kWh/yr2.5$1,073
Rinnai DONSR12Z72/DINLR12Z7215 kW heating13 kW cooling3,036 kWh/yr3$972
Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling3,628 kWh/yr2.5$1,161

Compare CRS13AS / ECA13AS & EFA13AS with another model

Actron Air CRS13AS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.02 kW
Cooling power input
3.89 kW
Rated heating capacity (7 Β°C)
15.00 kW
Heating power input
4.27 kW
EER, full load (tested)
3.27
COP, full load (tested)
3.43
Rated AEER
3.32
Rated ACOP
3.49
Standby power (PIA)
8.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRS13AS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,8021,819
Coldresidential2.51.58195,747
Mixedcommercial––2,270944
Mixedresidential2.52.01,2832,131
Hotcommercial––5,066199
Hotresidential2.52.53,772312
Part-load test points (20 values)
h__h2_ext_cap_power_rated
4716 W
c__t1_half_cap_power_rated
1414 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1575 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
13080 W
h__h1_half_cap_heat_cap_rated
7423 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3555.46 W
c__low_temp_half_cap_power_rated
1292.396 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6363 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
14022.539999999999 W
c__low_temp_half_cap_cooling_cap_rated
6852.951 W

Other model numbers on registration AAC7717

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7717
GEMS registration id
156207
Status
approved, available (self-reported)
Registration expires
19 August 2028
Registered for sale in
Australia, New Zealand
Family
CRS13AS / EVA13AS
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.