c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
1,067 kWh
382 cooling + 685 heating
Estimated running cost
$341 / year
$28 / month Β· $3,414 over 10 years
Capacity
5.2 kW cooling
5.6 kW heating

2% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 63% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air HRC-050DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,165$693$6,928
Mixed zone 1,067$341$3,414
Hot zone 1,202$385$3,846

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304

Air conditioners similar to the Actron Air HRC-050DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DN**A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320
Rinnai HONRJX50/HINRJX505.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,002 kWh/yr4$321
Spt AW052C-1 / AW052E5.6 kW heating5.2 kW cooling1,034 kWh/yr4.5$331
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNA1A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320
Rinnai HONRJ50B / HINRJ50B5.2 kW heating5.2 kW cooling1,018 kWh/yr4$326
Carrier Carrier Ambi5.6 kW heating5.2 kW cooling1,067 kWh/yr4$341

Compare HRC-050DS / HRE-050DS with another model

Actron Air HRC-050DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.35 kW
Rated heating capacity (7 Β°C)
5.59 kW
Heating power input
1.32 kW
EER, full load (tested)
3.86
COP, full load (tested)
4.22
Rated AEER
3.85
Rated ACOP
4.23
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.6 dB(A)
Outdoor sound power
66.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air HRC-050DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––382598
Coldresidential4.52.02391,926
Mixedcommercial––549300
Mixedresidential4.02.5382685
Hotcommercial––1,29159
Hotresidential4.53.51,10894
Part-load test points (23 values)
c__t1_min_cap_power_rated
480 W
h__h1_min_cap_power_rated
445 W
h__h2_ext_cap_power_rated
1630 W
c__t1_half_cap_power_rated
615 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
535 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2400 W
h__h2_ext_cap_heat_cap_rated
4700 W
h__h1_half_cap_heat_cap_rated
2850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
355 W
c__t1_min_cap_cooling_cap_rated
1900 W
c__low_temp_half_cap_power_rated
390 W
c__t1_half_cap_cooling_cap_rated
2600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2430 W
c__low_temp_half_cap_cooling_cap_rated
2610 W

Australian GEMS registration details

Registration number
AAC10068
GEMS registration id
178797
Status
approved, available (self-reported)
Registration expires
19 April 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.