Midea MFCA50VA-W/MFCA50VA-N is a 5.2 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7448).
- Energy rating (cooling)
- 4
- Heating: 3
- Annual electricity use
- 1,002 kWh
- 382 cooling + 620 heating
- Estimated running cost
- $321 / year
- $27 / month Β· $3,206 over 10 years
- Capacity
- 5.2 kW cooling
- 5.2 kW heating
8% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 89% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea MFCA50VA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,841 | $589 | $5,891 |
| Mixed zone | 1,002 | $321 | $3,206 |
| Hot zone | 1,195 | $382 | $3,824 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr | 4 | $268 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr | 4 | $271 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr | 4 | $304 |
Air conditioners similar to the Midea MFCA50VA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier Carrier Ambi5.6 kW heating5.2 kW cooling1,067 kWh/yr | 4 | $341 | |
| Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling983 kWh/yr | 4.5 | $315 | |
| Actron Air HRC-050DS / HRE-050DS5.6 kW heating5.2 kW cooling1,067 kWh/yr | 4 | $341 | |
| Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DN**A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr | 4.5 | $320 | |
| Rinnai HONRJX50/HINRJX505.2 kW heating5.2 kW cooling983 kWh/yr | 4.5 | $315 | |
| Spt AW052C-1 / AW052E5.6 kW heating5.2 kW cooling1,034 kWh/yr | 4.5 | $331 | |
| Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNA1A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr | 4.5 | $320 | |
| Rinnai HONRJ50B / HINRJ50B5.2 kW heating5.2 kW cooling1,018 kWh/yr | 4 | $326 |
Compare MFCA50VA-W/MFCA50VA-N with another model
Midea MFCA50VA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 5.20 kW
- Cooling power input
- 1.36 kW
- Rated heating capacity (7 Β°C)
- 5.20 kW
- Heating power input
- 1.24 kW
- EER, full load (tested)
- 3.93
- COP, full load (tested)
- 4.23
- Rated AEER
- 3.81
- Rated ACOP
- 4.17
- Standby power (PIA)
- 1.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 61.4 dB(A)
- Outdoor sound power
- 65.8 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFCA50VA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 320 | 516 |
| Coldresidential | residential | 4.5 | 2.5 | 239 | 1,602 |
| Mixedcommercial | commercial | β | β | 524 | 277 |
| Mixedresidential | residential | 4.0 | 3.0 | 382 | 620 |
| Hotcommercial | commercial | β | β | 1,274 | 57 |
| Hotresidential | residential | 4.5 | 3.5 | 1,105 | 90 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 578 W
- h__h1_min_cap_power_rated
- 430 W
- h__h2_ext_cap_power_rated
- 2470 W
- c__t1_half_cap_power_rated
- 610 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 490 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2320 W
- h__h2_ext_cap_heat_cap_rated
- 7030 W
- h__h1_half_cap_heat_cap_rated
- 2670 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 380 W
- c__t1_min_cap_cooling_cap_rated
- 2655 W
- c__low_temp_full_cap_power_rated
- 1243.04 W
- c__low_temp_half_cap_power_rated
- 390 W
- c__t1_half_cap_cooling_cap_rated
- 2830 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2600 W
- c__low_temp_full_cap_cooling_cap_rated
- 5600.4 W
- c__low_temp_half_cap_cooling_cap_rated
- 2720 W
Australian GEMS registration details
- Registration number
- AAC7448
- GEMS registration id
- 153905
- Status
- approved, available (self-reported)
- Registration expires
- 25 April 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.