c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,598 kWh
880 cooling + 1,718 heating
Estimated running cost
$831 / year
$69 / month Β· $8,314 over 10 years
Capacity
11.8 kW cooling
12.5 kW heating

8% less electricity than the median of 17 comparable 12.5 kW reverse cycle fixed registrations (2,836 kWh a year) in the mixed zone. Uses less than 71% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air MRC-120CS-5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,230$1,674$16,736
Mixed zone 2,598$831$8,314
Hot zone 2,710$867$8,672

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 11.8 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling2,217 kWh/yr3.5$709
Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling2,278 kWh/yr3$729
Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling2,278 kWh/yr3$729
Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling2,399 kWh/yr3.5$768
Midea MULMI0511B11 kW heating10.5 kW cooling2,409 kWh/yr3$771

Air conditioners similar to the Actron Air MRC-120CS-5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MXZ-6F120VGD13.2 kW heating12 kW cooling2,618 kWh/yr3.5$838
Kaden KM4612 kW heating12 kW cooling2,727 kWh/yr3$873
Samsung Electronics AJ120HCJ5KG13.5 kW heating12 kW cooling2,842 kWh/yr3$909
Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling2,399 kWh/yr3.5$768
Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling2,512 kWh/yr3.5$804
TCL FMA-42I5HD/DVO12 kW heating11.5 kW cooling2,836 kWh/yr2.5$908
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling2,448 kWh/yr3.5$783
Bonaire H5M125S2AE13.5 kW heating12.3 kW cooling2,850 kWh/yr3$912

Compare MRC-120CS-5 with another model

Actron Air MRC-120CS-5 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
11.85 kW
Cooling power input
3.15 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
3.25 kW
EER, full load (tested)
3.73
COP, full load (tested)
3.81
Rated AEER
3.69
Rated ACOP
3.77
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
73 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air MRC-120CS-5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8181,487
Coldresidential4.02.05564,674
Mixedcommercial––1,203778
Mixedresidential3.52.58801,718
Hotcommercial––2,811183
Hotresidential4.53.02,434276
Part-load test points (25 values)
c__t1_min_cap_power_rated
560 W
h__h1_min_cap_power_rated
605 W
h__h2_ext_cap_power_rated
3270 W
c__t1_half_cap_power_rated
1160 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1280 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2660 W
h__h2_ext_cap_heat_cap_rated
9940 W
h__h1_half_cap_heat_cap_rated
6300 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
450 W
c__t1_min_cap_cooling_cap_rated
2880 W
c__low_temp_full_cap_power_rated
2879.1 W
c__low_temp_half_cap_power_rated
755 W
c__t1_half_cap_cooling_cap_rated
5780 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3950 W
c__low_temp_full_cap_cooling_cap_rated
12762.449999999999 W
c__low_temp_half_cap_cooling_cap_rated
5750 W

Australian GEMS registration details

Registration number
AAC6565
GEMS registration id
143625
Status
approved, available (self-reported)
Registration expires
29 March 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.