c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,139 kWh
807 cooling + 1,332 heating
Estimated running cost
$684 / year
$57 / month Β· $6,845 over 10 years
Capacity
10 kW cooling
10.5 kW heating

4% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 63% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air URC-100DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,000$1,280$12,800
Mixed zone 2,139$684$6,845
Hot zone 2,489$796$7,965

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr4$602
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602

Air conditioners similar to the Actron Air URC-100DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling2,139 kWh/yr3.5$684
Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,188 kWh/yr3.5$700
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling1,918 kWh/yr3.5$614
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Daikin RZAV100F2V1 / FCA100CVMA12 kW heating10 kW cooling1,975 kWh/yr4$632
Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,202 kWh/yr3.5$705
Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling2,229 kWh/yr3$713
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477

Compare URC-100DS / CRE-100DS with another model

Actron Air URC-100DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
3.04 kW
Rated heating capacity (7 Β°C)
10.50 kW
Heating power input
2.56 kW
EER, full load (tested)
3.25
COP, full load (tested)
4.11
Rated AEER
3.26
Rated ACOP
4.04
Standby power (PIA)
9.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
66.1 dB(A)
Outdoor sound power
70.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-100DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5491,126
Coldresidential3.52.05063,494
Mixedcommercial––972600
Mixedresidential3.52.58071,332
Hotcommercial––2,498134
Hotresidential4.03.02,283206
Part-load test points (23 values)
c__t1_min_cap_power_rated
735 W
h__h1_min_cap_power_rated
555 W
h__h2_ext_cap_power_rated
3255 W
c__t1_half_cap_power_rated
1300 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1085 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2660 W
h__h2_ext_cap_heat_cap_rated
10200 W
h__h1_half_cap_heat_cap_rated
5500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
455 W
c__t1_min_cap_cooling_cap_rated
2900 W
c__low_temp_half_cap_power_rated
800 W
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3200 W
c__low_temp_half_cap_cooling_cap_rated
5100 W

Australian GEMS registration details

Registration number
AAC9028
GEMS registration id
170376
Status
approved, available (self-reported)
Registration expires
22 June 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.