Australia Β· costs in AUD

Reverse cycle split system air conditioner, cassette
Midea UCMI105OC/CASMI105IC Air Conditioner
Midea UCMI105OC/CASMI105IC is a 10 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9170).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,139 kWh
- 807 cooling + 1,332 heating
- Estimated running cost
- $684 / year
- $57 / month Β· $6,845 over 10 years
- Capacity
- 10 kW cooling
- 10.5 kW heating
4% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 63% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea UCMI105OC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,000 | $1,280 | $12,800 |
| Mixed zone | 2,139 | $684 | $6,845 |
| Hot zone | 2,489 | $796 | $7,965 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr | 3.5 | $591 | |
| Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 | |
| Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 | |
| Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 |
Air conditioners similar to the Midea UCMI105OC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,188 kWh/yr | 3.5 | $700 | |
| Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr | 3.5 | $591 | |
| Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,202 kWh/yr | 3.5 | $705 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Daikin RZAV100F2Y1 / FCA100CVMA12 kW heating10 kW cooling1,975 kWh/yr | 4 | $632 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling1,918 kWh/yr | 3.5 | $614 | |
| Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling2,229 kWh/yr | 3 | $713 | |
| Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling2,139 kWh/yr | 3.5 | $684 |
Compare UCMI105OC/CASMI105IC with another model
Midea UCMI105OC specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 3.04 kW
- Rated heating capacity (7 Β°C)
- 10.50 kW
- Heating power input
- 2.56 kW
- EER, full load (tested)
- 3.25
- COP, full load (tested)
- 4.11
- Rated AEER
- 3.26
- Rated ACOP
- 4.04
- Standby power (PIA)
- 9.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 66.1 dB(A)
- Outdoor sound power
- 70.6 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea UCMI105OC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 549 | 1,126 |
| Coldresidential | residential | 3.5 | 2.0 | 506 | 3,494 |
| Mixedcommercial | commercial | β | β | 972 | 600 |
| Mixedresidential | residential | 3.5 | 2.5 | 807 | 1,332 |
| Hotcommercial | commercial | β | β | 2,498 | 134 |
| Hotresidential | residential | 4.0 | 3.0 | 2,283 | 206 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 735 W
- h__h1_min_cap_power_rated
- 555 W
- h__h2_ext_cap_power_rated
- 3255 W
- c__t1_half_cap_power_rated
- 1300 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1085 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2660 W
- h__h2_ext_cap_heat_cap_rated
- 10200 W
- h__h1_half_cap_heat_cap_rated
- 5500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 455 W
- c__t1_min_cap_cooling_cap_rated
- 2900 W
- c__low_temp_half_cap_power_rated
- 800 W
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3200 W
- c__low_temp_half_cap_cooling_cap_rated
- 5100 W
Australian GEMS registration details
- Registration number
- AAC9170
- GEMS registration id
- 170219
- Status
- approved, available (self-reported)
- Registration expires
- 4 August 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.