Australia Β· costs in AUD

Reverse cycle packaged air conditioner
APAC P012AHR3SA-LBB Air Conditioner
APAC P012AHR3SA-LBB is a 11.4 kW reverse cycle ducted packaged air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7271).
- Energy rating (cooling)
- 1
- Heating: 1.5
- Annual electricity use
- 3,584 kWh
- 1,523 cooling + 2,061 heating
- Estimated running cost
- $1,147 / year
- $96 / month Β· $11,469 over 10 years
- Capacity
- 11.4 kW cooling
- 11.7 kW heating
Only 3 comparable registrations in this cohort, so no percentile is shown.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 28% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
APAC P012AHR3SA-LBB running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,131 | $1,962 | $19,619 |
| Mixed zone | 3,584 | $1,147 | $11,469 |
| Hot zone | 4,573 | $1,463 | $14,634 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 11.4 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA116RKTY10.8 kW heating11.3 kW cooling3,352 kWh/yr | 1.5 | $1,073 |
Air conditioners similar to the APAC P012AHR3SA-LBB
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA116RKTY10.8 kW heating11.3 kW cooling3,352 kWh/yr | 1.5 | $1,073 |
Other APAC models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P012AVR3SA-LTS11.7 kW heating11.4 kW cooling3,584 kWh/yr | 1 | $1,147 | |
| APAC P012AVR3SA-LTR11.7 kW heating11.4 kW cooling3,584 kWh/yr | 1 | $1,147 |
Compare P012AHR3SA-LBB with another model
APAC P012AHR3SA-LBB specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 11.38 kW
- Cooling power input
- 3.30 kW
- Rated heating capacity (7 Β°C)
- 11.74 kW
- Heating power input
- 2.97 kW
- EER, full load (tested)
- 3.28
- COP, full load (tested)
- 3.76
- Rated AEER
- 3.29
- Rated ACOP
- 3.76
- Standby power (PIA)
- 46.2 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC P012AHR3SA-LBB zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,152 | 1,752 |
| Coldresidential | residential | 1.0 | 1.5 | 1,033 | 5,098 |
| Mixedcommercial | commercial | β | β | 2,648 | 977 |
| Mixedresidential | residential | 1.0 | 1.5 | 1,523 | 2,061 |
| Hotcommercial | commercial | β | β | 5,606 | 276 |
| Hotresidential | residential | 1.5 | 1.5 | 4,163 | 410 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 2740 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 9480 W
- c__low_temp_full_cap_power_rated
- 2950 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 12270 W
Other model numbers on registration AAC7271
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC7271
- GEMS registration id
- 152687
- Status
- approved, available (self-reported)
- Registration expires
- 20 February 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- P012AHR3SA-
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 6
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.