c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,112 kWh
412 cooling + 700 heating
Estimated running cost
$356 / year
$30 / month Β· $3,558 over 10 years
Capacity
5.2 kW cooling
5.5 kW heating

2% more electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 39% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 74% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Braemar WCHV50D1T running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,170$694$6,944
Mixed zone 1,112$356$3,558
Hot zone 1,324$424$4,237

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304

Air conditioners similar to the Braemar WCHV50D1T

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DN**A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320
Actron Air HRC-050DS / HRE-050DS5.6 kW heating5.2 kW cooling1,067 kWh/yr4$341
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,002 kWh/yr4$321
Rinnai HONRJX50/HINRJX505.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Spt AW052C-1 / AW052E5.6 kW heating5.2 kW cooling1,034 kWh/yr4.5$331
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNA1A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320
Rinnai HONRJ50B / HINRJ50B5.2 kW heating5.2 kW cooling1,018 kWh/yr4$326

Compare WCHV50D1T/WSHV50D1T with another model

Braemar WCHV50D1T specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.35 kW
Rated heating capacity (7 Β°C)
5.50 kW
Heating power input
1.40 kW
EER, full load (tested)
3.87
COP, full load (tested)
4.11
Rated AEER
3.79
Rated ACOP
3.87
Standby power (PIA)
6.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.2 dB(A)
Outdoor sound power
66.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar WCHV50D1T zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––477604
Coldresidential3.52.02671,903
Mixedcommercial––623313
Mixedresidential3.52.5412700
Hotcommercial––1,58371
Hotresidential4.03.01,214110
Part-load test points (23 values)
c__t1_min_cap_power_rated
210 W
h__h2_ext_cap_power_rated
2000 W
c__t1_half_cap_power_rated
500 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
550 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5220 W
h__h1_half_cap_heat_cap_rated
2970 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
190 W
c__t1_min_cap_cooling_cap_rated
1010 W
c__low_temp_full_cap_power_rated
1233.9 W
c__low_temp_half_cap_power_rated
457 W
c__t1_half_cap_cooling_cap_rated
2600 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1640 W
c__low_temp_full_cap_cooling_cap_rated
5600.4 W
c__low_temp_half_cap_cooling_cap_rated
2800.2 W

Australian GEMS registration details

Registration number
AAC6686
GEMS registration id
145297
Status
approved, available (self-reported)
Registration expires
12 May 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.