c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,125 kWh
717 cooling + 1,408 heating
Estimated running cost
$680 / year
$57 / month Β· $6,800 over 10 years
Capacity
9.1 kW cooling
10.1 kW heating

5% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 66% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QHB090N8-1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,554$1,457$14,573
Mixed zone 2,125$680$6,800
Hot zone 2,316$741$7,411

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Carrier 38QHB090N8-1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Westinghouse HSV307HWAE/HSV307HWAI10.4 kW heating9.1 kW cooling2,164 kWh/yr4$692
Westinghouse WSD91HWB-I/WSD91HWA-E10.4 kW heating9.1 kW cooling2,164 kWh/yr4$692
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kogan KASSSAC90HE9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Kogan KASSSAC90HF9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kaden KSI-9.09.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling1,882 kWh/yr4$602

Compare 38QHB090N8-1/42QHB090N8-1 with another model

Carrier 38QHB090N8-1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.10 kW
Cooling power input
2.59 kW
Rated heating capacity (7 Β°C)
10.10 kW
Heating power input
2.90 kW
EER, full load (tested)
3.53
COP, full load (tested)
3.51
Rated AEER
3.51
Rated ACOP
3.48
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
51 dB(A)
Outdoor sound power
64.4 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QHB090N8-1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7481,245
Coldresidential4.01.54484,106
Mixedcommercial––1,066582
Mixedresidential3.52.07171,408
Hotcommercial––2,683109
Hotresidential4.03.02,141175
Part-load test points (23 values)
c__t1_min_cap_power_rated
650 W
h__h1_min_cap_power_rated
570 W
h__h2_ext_cap_power_rated
2910 W
c__t1_half_cap_power_rated
970 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1020 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2910 W
h__h2_ext_cap_heat_cap_rated
7320 W
h__h1_half_cap_heat_cap_rated
5090 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
470 W
c__t1_min_cap_cooling_cap_rated
3130 W
c__low_temp_half_cap_power_rated
770 W
c__t1_half_cap_cooling_cap_rated
4540 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3300 W
c__low_temp_half_cap_cooling_cap_rated
4900 W

Australian GEMS registration details

Registration number
AAC8823
GEMS registration id
169299
Status
approved, available (self-reported)
Registration expires
15 June 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.