c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
2,164 kWh
658 cooling + 1,506 heating
Estimated running cost
$692 / year
$58 / month Β· $6,925 over 10 years
Capacity
9.1 kW cooling
10.4 kW heating

3% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 60% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WSD91HWB-I running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,785$1,531$15,312
Mixed zone 2,164$692$6,925
Hot zone 2,171$695$6,947

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Westinghouse WSD91HWB-I

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QHB090N8-1/42QHB090N8-110.1 kW heating9.1 kW cooling2,125 kWh/yr3.5$680
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kogan KASSSAC90HC9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Kogan KASSSAC90HB9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr4$602
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kaden KSI-9.09.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling1,882 kWh/yr4$602

Compare WSD91HWB-I/WSD91HWA-E with another model

Westinghouse WSD91HWB-I specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.10 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
10.40 kW
Heating power input
–
EER, full load (tested)
3.79
COP, full load (tested)
3.43
Rated AEER
3.82
Rated ACOP
3.38
Standby power (PIA)
1.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61.7 dB(A)
Outdoor sound power
68.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD91HWB-I zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3421,316
Coldresidential4.51.54204,365
Mixedcommercial––679614
Mixedresidential4.02.06581,506
Hotcommercial––1,068116
Hotresidential4.53.01,984187
Part-load test points (23 values)
c__t1_min_cap_power_rated
830 W
h__h1_min_cap_power_rated
537 W
h__h2_ext_cap_power_rated
3147 W
c__t1_half_cap_power_rated
1060 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1086 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2700 W
h__h2_ext_cap_heat_cap_rated
7600 W
h__h1_half_cap_heat_cap_rated
5100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
439 W
c__t1_min_cap_cooling_cap_rated
3240 W
c__low_temp_half_cap_power_rated
745 W
c__t1_half_cap_cooling_cap_rated
4500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3100 W
c__low_temp_half_cap_cooling_cap_rated
4550 W

Other model numbers on registration AAC7558

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7558
GEMS registration id
–
Status
approved
Registration expires
7 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD91HWA-E/WSD91HWA-I
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9