c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
2,164 kWh
658 cooling + 1,506 heating
Estimated running cost
$692 / year
$58 / month Β· $6,925 over 10 years
Capacity
9.1 kW cooling
10.4 kW heating

3% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 60% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WSD91HWA-E running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,785$1,531$15,312
Mixed zone 2,164$692$6,925
Hot zone 2,171$695$6,947

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DN**E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Westinghouse WSD91HWA-E

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QHB090N8-1/42QHB090N8-110.1 kW heating9.1 kW cooling2,125 kWh/yr3.5$680
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kogan KASSSAC90HF9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Kogan KASSSAC90HB9.5 kW heating9 kW cooling1,917 kWh/yr3$613
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr4$602
Kaden KSI-9.09.5 kW heating9 kW cooling1,882 kWh/yr4$602
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling1,882 kWh/yr4$602

Compare WSD91HWA-E/WSD91HWA-I with another model

Westinghouse WSD91HWA-E specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.10 kW
Cooling power input
2.38 kW
Rated heating capacity (7 Β°C)
10.40 kW
Heating power input
3.07 kW
EER, full load (tested)
3.79
COP, full load (tested)
3.43
Rated AEER
3.82
Rated ACOP
3.38
Standby power (PIA)
1.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61.7 dB(A)
Outdoor sound power
68.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD91HWA-E zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3421,316
Coldresidential4.51.54204,365
Mixedcommercial––679614
Mixedresidential4.02.06581,506
Hotcommercial––1,068116
Hotresidential4.53.01,984187
Part-load test points (23 values)
c__t1_min_cap_power_rated
830 W
h__h1_min_cap_power_rated
537 W
h__h2_ext_cap_power_rated
3147 W
c__t1_half_cap_power_rated
1060 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1086 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2700 W
h__h2_ext_cap_heat_cap_rated
7600 W
h__h1_half_cap_heat_cap_rated
5100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
439 W
c__t1_min_cap_cooling_cap_rated
3240 W
c__low_temp_half_cap_power_rated
745 W
c__t1_half_cap_cooling_cap_rated
4500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3100 W
c__low_temp_half_cap_cooling_cap_rated
4550 W

Other model numbers on registration AAC7558

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7558
GEMS registration id
154750
Status
approved, available (self-reported)
Registration expires
7 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD91HWA-E/WSD91HWA-I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.