c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,360 kWh
832 cooling + 1,528 heating
Estimated running cost
$755 / year
$63 / month Β· $7,552 over 10 years
Capacity
10.2 kW cooling
12 kW heating

3% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 63% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 45% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier 38QSP105N8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,767$1,525$15,254
Mixed zone 2,360$755$7,552
Hot zone 2,580$826$8,256

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr3.5$620

Air conditioners similar to the Carrier 38QSP105N8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI90OC/DUCMI90IC12 kW heating10.2 kW cooling2,360 kWh/yr3.5$755
Actron Air URC-100DS / LRE-100DS12 kW heating10.2 kW cooling2,360 kWh/yr3.5$755
Haier 1U105S5SN5FA / AD105S2SH5FA10.8 kW heating10.3 kW cooling2,514 kWh/yr2.5$804
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr4$678
Daikin RZAV100F2Y1 / FBA100BVMA12 kW heating10 kW cooling2,230 kWh/yr3$714
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464

Compare 38QSP105N8/42QSP105N8 with another model

Carrier 38QSP105N8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.20 kW
Cooling power input
3.05 kW
Rated heating capacity (7 Β°C)
12.00 kW
Heating power input
3.00 kW
EER, full load (tested)
3.26
COP, full load (tested)
4.16
Rated AEER
3.30
Rated ACOP
3.95
Standby power (PIA)
10.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSP105N8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3291,310
Coldresidential3.52.05284,239
Mixedcommercial––929666
Mixedresidential3.52.58321,528
Hotcommercial––2,516146
Hotresidential4.03.52,354226
Part-load test points (23 values)
c__t1_min_cap_power_rated
605 W
h__h1_min_cap_power_rated
530 W
h__h2_ext_cap_power_rated
3230 W
c__t1_half_cap_power_rated
1460 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1180 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2700 W
h__h2_ext_cap_heat_cap_rated
9800 W
h__h1_half_cap_heat_cap_rated
6100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
365 W
c__t1_min_cap_cooling_cap_rated
2300 W
c__low_temp_half_cap_power_rated
910 W
c__t1_half_cap_cooling_cap_rated
5100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2400 W
c__low_temp_half_cap_cooling_cap_rated
5550 W

Australian GEMS registration details

Registration number
AAC9324
GEMS registration id
172308
Status
approved, available (self-reported)
Registration expires
27 August 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.