Australia Β· costs in AUD

Reverse cycle split system air conditioner
Midea UCMI90OC/DUCMI90IC Air Conditioner
Midea UCMI90OC/DUCMI90IC is a 10.2 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8840).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,360 kWh
- 832 cooling + 1,528 heating
- Estimated running cost
- $755 / year
- $63 / month Β· $7,552 over 10 years
- Capacity
- 10.2 kW cooling
- 12 kW heating
3% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 63% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 45% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea UCMI90OC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,767 | $1,525 | $15,254 |
| Mixed zone | 2,360 | $755 | $7,552 |
| Hot zone | 2,580 | $826 | $8,256 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10.2 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr | 4.5 | $602 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr | 3.5 | $603 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr | 3.5 | $620 |
Air conditioners similar to the Midea UCMI90OC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air URC-100DS / LRE-100DS12 kW heating10.2 kW cooling2,360 kWh/yr | 3.5 | $755 | |
| Carrier 38QSP105N8/42QSP105N812 kW heating10.2 kW cooling2,360 kWh/yr | 3.5 | $755 | |
| Carrier 38QSM105D8S/42QSM105D8S10.9 kW heating10.2 kW cooling2,262 kWh/yr | 3.5 | $724 | |
| Haier 1U105S5SN5FA / AD105S2SH5FA10.8 kW heating10.3 kW cooling2,514 kWh/yr | 2.5 | $804 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr | 4.5 | $602 | |
| Daikin RZAV100F2Y1 / FBA100BVMA12 kW heating10 kW cooling2,230 kWh/yr | 3 | $714 | |
| Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 |
Compare UCMI90OC/DUCMI90IC with another model
Midea UCMI90OC specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.20 kW
- Cooling power input
- 3.05 kW
- Rated heating capacity (7 Β°C)
- 12.00 kW
- Heating power input
- 3.00 kW
- EER, full load (tested)
- 3.26
- COP, full load (tested)
- 4.16
- Rated AEER
- 3.30
- Rated ACOP
- 3.95
- Standby power (PIA)
- 10.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 68.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea UCMI90OC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 329 | 1,310 |
| Coldresidential | residential | 3.5 | 2.0 | 528 | 4,239 |
| Mixedcommercial | commercial | β | β | 929 | 666 |
| Mixedresidential | residential | 3.5 | 2.5 | 832 | 1,528 |
| Hotcommercial | commercial | β | β | 2,516 | 146 |
| Hotresidential | residential | 4.0 | 3.5 | 2,354 | 226 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 605 W
- h__h1_min_cap_power_rated
- 530 W
- h__h2_ext_cap_power_rated
- 3230 W
- c__t1_half_cap_power_rated
- 1460 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1180 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2700 W
- h__h2_ext_cap_heat_cap_rated
- 9800 W
- h__h1_half_cap_heat_cap_rated
- 6100 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 365 W
- c__t1_min_cap_cooling_cap_rated
- 2300 W
- c__low_temp_half_cap_power_rated
- 910 W
- c__t1_half_cap_cooling_cap_rated
- 5100 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2400 W
- c__low_temp_half_cap_cooling_cap_rated
- 5550 W
Australian GEMS registration details
- Registration number
- AAC8840
- GEMS registration id
- 169116
- Status
- approved, available (self-reported)
- Registration expires
- 11 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.