c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,571 kWh
578 cooling + 993 heating
Estimated running cost
$503 / year
$42 / month Β· $5,027 over 10 years
Capacity
7 kW cooling
7.9 kW heating

2% less electricity than the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 60% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Comfee CASG-XG70 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,072$983$9,830
Mixed zone 1,571$503$5,027
Hot zone 1,860$595$5,952

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr4.5$410
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr4.5$439
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr3$448

Air conditioners similar to the Comfee CASG-XG70

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 42QHG070N8PB/38QUH070N8PB7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Kaden KSI-7.07.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Kaden KSI247.5 kW heating7 kW cooling1,518 kWh/yr3.5$486
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling1,509 kWh/yr3.5$483
Midea MFAB-70WD/MFAB-70ND7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Hitachi RAC-VJ70PHAT/RAK-VJ70PHAT8 kW heating7 kW cooling1,453 kWh/yr4$465

Compare CASG-XG70/CASN-XG70 with another model

Comfee CASG-XG70 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
1.92 kW
Rated heating capacity (7 Β°C)
7.90 kW
Heating power input
1.99 kW
EER, full load (tested)
3.54
COP, full load (tested)
3.74
Rated AEER
3.64
Rated ACOP
3.96
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.2 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Comfee CASG-XG70 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––680839
Coldresidential3.52.03662,706
Mixedcommercial––921430
Mixedresidential3.52.5578993
Hotcommercial––2,22285
Hotresidential3.53.01,724136
Part-load test points (25 values)
c__t1_min_cap_power_rated
630 W
h__h1_min_cap_power_rated
460 W
h__h2_ext_cap_power_rated
2970 W
c__t1_half_cap_power_rated
720 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2380 W
h__h2_ext_cap_heat_cap_rated
7780 W
h__h1_half_cap_heat_cap_rated
3790 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
490 W
c__t1_min_cap_cooling_cap_rated
2860 W
c__low_temp_full_cap_power_rated
1754.88 W
c__low_temp_half_cap_power_rated
620 W
c__t1_half_cap_cooling_cap_rated
3300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3100 W
c__low_temp_full_cap_cooling_cap_rated
7539 W
c__low_temp_half_cap_cooling_cap_rated
3700 W

Australian GEMS registration details

Registration number
AAC7814
GEMS registration id
157040
Status
approved, available (self-reported)
Registration expires
8 October 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.