c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
1,978 kWh
700 cooling + 1,278 heating
Estimated running cost
$633 / year
$53 / month Β· $6,330 over 10 years
Capacity
7.8 kW cooling
9 kW heating

8% more electricity than the median of 125 comparable 8 kW reverse cycle split system registrations (1,834 kWh a year) in the mixed zone. Uses less than 33% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Daikin RXF80AVMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,967$1,269$12,694
Mixed zone 1,978$633$6,330
Hot zone 2,233$715$7,146

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.8 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling1,404 kWh/yr4$449
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,426 kWh/yr3$456
Kogan KASSSAC71HF7.5 kW heating7.1 kW cooling1,433 kWh/yr4$459
Kogan KASSSAC71HA7.5 kW heating7.1 kW cooling1,433 kWh/yr4$459
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling1,441 kWh/yr3$461

Air conditioners similar to the Daikin RXF80AVMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MUZ-AP80VG/MSZ-AP80VGD29 kW heating7.8 kW cooling1,886 kWh/yr3$604
Mitsubishi Electric MUZ-AP80VG/MSZ-AP80VGKD9 kW heating7.8 kW cooling1,886 kWh/yr3$604
Rinnai HSNRP80B8.3 kW heating7.8 kW cooling1,707 kWh/yr3.5$546
Hisense HAWL80KR8.2 kW heating7.8 kW cooling1,983 kWh/yr2.5$635
Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling1,701 kWh/yr3.5$544
Carrier 42QHG080N8PB/38QUH080N8PB8.2 kW heating7.7 kW cooling1,718 kWh/yr3.5$550
Midea MFAB-80WD/MFAB-80ND8.2 kW heating7.7 kW cooling1,718 kWh/yr3.5$550
Midea MFAG80VB-W/MFAG80VB-N8.2 kW heating7.7 kW cooling1,718 kWh/yr3.5$550

Compare RXF80AVMA / FTXF80AVMA with another model

Daikin RXF80AVMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.80 kW
Cooling power input
2.38 kW
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
2.40 kW
EER, full load (tested)
3.17
COP, full load (tested)
3.72
Rated AEER
3.26
Rated ACOP
3.73
Standby power (PIA)
4.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
66 dB(A)
Outdoor sound power
66 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXF80AVMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8911,112
Coldresidential3.01.54383,529
Mixedcommercial––1,164568
Mixedresidential3.02.07001,278
Hotcommercial––2,669119
Hotresidential3.02.52,046187
Part-load test points (18 values)
h__h2_ext_cap_power_rated
3150 W
c__t1_half_cap_power_rated
787 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
960 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7700 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
678 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3900 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
4200 W

Australian GEMS registration details

Registration number
AAC10286
GEMS registration id
180740
Status
approved, available (self-reported)
Registration expires
7 July 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9