c/kWh
Energy rating (cooling)
1.5
Heating: 2
Annual electricity use
689 kWh
302 cooling + 387 heating
Estimated running cost
$220 / year
$18 / month Β· $2,205 over 10 years
Capacity
2.4 kW cooling
2.6 kW heating

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 86% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

DualVent YWD-08HD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,251$400$4,003
Mixed zone 689$220$2,205
Hot zone 957$306$3,062

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Olimpia Splendid 02011 Unico Pro Inverter 12 HP AUNZ2 kW heating2.1 kW cooling608 kWh/yr2$195

Air conditioners similar to the DualVent YWD-08HD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Innova 2.0 COMS12OCEII2.4 kW heating2.4 kW cooling709 kWh/yr2$227
Innova 2.0 CZMO12IC3II2.4 kW heating2.4 kW cooling709 kWh/yr2$227
Airtemp ATC-32DDNO H/C INVERTER-M72.3 kW heating2.5 kW cooling749 kWh/yr1.5$240
Olimpia Splendid 02011 Unico Pro Inverter 12 HP AUNZ2 kW heating2.1 kW cooling608 kWh/yr2$195

Compare YWD-08HD/FC-3 with another model

DualVent YWD-08HD specifications

Type
Reverse cycle
Configuration
Double-duct wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.35 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
2.63 kW
Heating power input
–
EER, full load (tested)
3.03
COP, full load (tested)
3.49
Rated AEER
3.04
Rated ACOP
3.58
Standby power (PIA)
1.3 W
Compressor
Variable speed, Inverter
Refrigerant
R290
Power supply
Single phase
Indoor sound power
59.2 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

DualVent YWD-08HD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––508334
Coldresidential1.51.51971,054
Mixedcommercial––603172
Mixedresidential1.52.0302387
Hotcommercial––1,27936
Hotresidential1.52.590057
Part-load test points (20 values)
h__h2_ext_cap_power_rated
750 W
c__t1_half_cap_power_rated
320 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2100 W
h__h1_half_cap_heat_cap_rated
1350 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
703.78 W
c__low_temp_half_cap_power_rated
320 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
2530.95 W
c__low_temp_half_cap_cooling_cap_rated
1200 W

Other model numbers on registration AAC7615

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7615
GEMS registration id
–
Status
approved
Registration expires
3 July 2028
Registered for sale in
Australia
Family
DualVent
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
1

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.