c/kWh
Energy rating (cooling)
1.5
Heating: 2
Annual electricity use
689 kWh
302 cooling + 387 heating
Estimated running cost
$220 / year
$18 / month Β· $2,205 over 10 years
Capacity
2.4 kW cooling
2.6 kW heating

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 86% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

DualVent YWD1-08HD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,251$400$4,003
Mixed zone 689$220$2,205
Hot zone 957$306$3,062

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Olimpia Splendid 02011 Unico Pro Inverter 12 HP AUNZ2 kW heating2.1 kW cooling608 kWh/yr2$195

Air conditioners similar to the DualVent YWD1-08HD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Innova 2.0 COMS12OC4II2.4 kW heating2.4 kW cooling709 kWh/yr2$227
Innova 2.0 C3MS12IC3II2.4 kW heating2.4 kW cooling709 kWh/yr2$227
Airtemp ATC-32DDNO H/C INVERTER-M72.3 kW heating2.5 kW cooling749 kWh/yr1.5$240
Olimpia Splendid 02011 Unico Pro Inverter 12 HP AUNZ2 kW heating2.1 kW cooling608 kWh/yr2$195

Compare YWD1-08HD/FC-3-W with another model

DualVent YWD1-08HD specifications

Type
Reverse cycle
Configuration
Double-duct wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.35 kW
Cooling power input
0.77 kW
Rated heating capacity (7 Β°C)
2.63 kW
Heating power input
0.73 kW
EER, full load (tested)
3.03
COP, full load (tested)
3.49
Rated AEER
3.03
Rated ACOP
3.58
Standby power (PIA)
1.3 W
Compressor
Variable speed, Inverter
Refrigerant
R290
Power supply
Single phase
Indoor sound power
59.2 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

DualVent YWD1-08HD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––508334
Coldresidential1.51.51971,054
Mixedcommercial––603172
Mixedresidential1.52.0302387
Hotcommercial––1,27936
Hotresidential1.52.590057
Part-load test points (20 values)
h__h2_ext_cap_power_rated
750 W
c__t1_half_cap_power_rated
320 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2100 W
h__h1_half_cap_heat_cap_rated
1350 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
703.78 W
c__low_temp_half_cap_power_rated
320 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
2530.95 W
c__low_temp_half_cap_cooling_cap_rated
1200 W

Other model numbers on registration AAC7615

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7615
GEMS registration id
154876
Status
approved, available (self-reported)
Registration expires
3 July 2028
Registered for sale in
Australia
Family
DualVent
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 1

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.