c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
1,374 kWh
521 cooling + 853 heating
Estimated running cost
$440 / year
$37 / month Β· $4,397 over 10 years
Capacity
5.2 kW cooling
6 kW heating

26% more electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 1% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Fujitsu AOTG18LACC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,686$860$8,595
Mixed zone 1,374$440$4,397
Hot zone 1,634$523$5,229

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304

Air conditioners similar to the Fujitsu AOTG18LACC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRJ50B / HINRJ50B5.2 kW heating5.2 kW cooling1,018 kWh/yr4$326
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Actron Air HRC-050DS / HRE-050DS5.6 kW heating5.2 kW cooling1,067 kWh/yr4$341
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,002 kWh/yr4$321
Rinnai HONRJX50/HINRJX505.2 kW heating5.2 kW cooling983 kWh/yr4.5$315
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNC8A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320
Spt AW052C-1 / AW052E5.6 kW heating5.2 kW cooling1,034 kWh/yr4.5$331
Gree GWH18QEXF-K6DNC8A/O / GWH18QEXF-K6DNA1A/I5.6 kW heating5.2 kW cooling1,000 kWh/yr4.5$320

Compare AOTG18LACC / ABTG18LVTA with another model

Fujitsu AOTG18LACC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.51 kW
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
1.66 kW
EER, full load (tested)
3.51
COP, full load (tested)
3.69
Rated AEER
3.39
Rated ACOP
3.57
Standby power (PIA)
6.7 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
990 Γ— 199 Γ— 655 mm
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG18LACC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––729738
Coldresidential2.51.53362,350
Mixedcommercial––914379
Mixedresidential2.52.0521853
Hotcommercial––2,01785
Hotresidential2.52.51,504130
Part-load test points (16 values)
h__h2_ext_cap_power_rated
1885 W
c__t1_half_cap_power_rated
580 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
620 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4900 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2600 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC8677
GEMS registration id
167898
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9