c/kWh
Energy rating (cooling)
2.5
Annual electricity use
904 kWh
Estimated running cost
$289 / year
$24 / month Β· $2,893 over 10 years
Capacity
9.4 kW cooling

10% more electricity than the median of 6 comparable 10 kW cooling only split system registrations (822 kWh a year) in the mixed zone. Uses less than 17% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 79% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Fujitsu AOTG34CMTA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 576$184$1,843
Mixed zone 904$289$2,893
Hot zone 2,647$847$8,470

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH30CNTA/ASTH30CNTA8.5 kW cooling651 kWh/yr4$208
Daikin RKM85WVMA / FTKM85WVMA8.5 kW cooling718 kWh/yr3$230
Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD2 Series9 kW cooling771 kWh/yr3$247
Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD9 kW cooling771 kWh/yr3$247
Fujitsu AOTH34CNTA/ASTH34CNTA9.5 kW cooling799 kWh/yr3.5$256

Air conditioners similar to the Fujitsu AOTG34CMTA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RKM95P2VMA / FTKM95P2VMA9.4 kW cooling944 kWh/yr2.5$302
Daikin RKM95WVMA / FTKM95WVMA9.5 kW cooling844 kWh/yr3$270
Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD9 kW cooling771 kWh/yr3$247
Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD2 Series9 kW cooling771 kWh/yr3$247

Other Fujitsu models of similar capacity

ModelStarsEst. cost / yrCompare
Fujitsu AOTH34CNTA/ASTH34CNTA9.5 kW cooling799 kWh/yr3.5$256
Fujitsu AOTH30CNTA/ASTH30CNTA8.5 kW cooling651 kWh/yr4$208

Compare AOTG34CMTA/ASTG34CMTA with another model

Fujitsu AOTG34CMTA specifications

Type
Cooling only
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.40 kW
Cooling power input
2.78 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.49
COP, full load (tested)
–
Rated AEER
3.36
Rated ACOP
–
Standby power (PIA)
5.9 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
1150 Γ— 340 Γ— 280 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG34CMTA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,216–
Coldresidential2.5–576–
Mixedcommercial––1,560–
Mixedresidential2.5–904–
Hotcommercial––3,505–
Hotresidential3.0–2,647–
Part-load test points (7 values)
c__t1_half_cap_power_rated
1080 W
c__t1_have_min_cap_results
No
c__low_temp_half_cap_power_rated
950 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5130 W

Australian GEMS registration details

Registration number
AAC8784
GEMS registration id
168673
Status
approved, available (self-reported)
Registration expires
8 April 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.