Australia Β· costs in AUD

Cooling only split system air conditioner, wall hung
Fujitsu AOTH34CNTA/ASTH34CNTA Air Conditioner
Fujitsu AOTH34CNTA/ASTH34CNTA is a 9.5 kW cooling only split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7623).
- Energy rating (cooling)
- 3.5
- Annual electricity use
- 799 kWh
- Estimated running cost
- $256 / year
- $21 / month Β· $2,557 over 10 years
- Capacity
- 9.5 kW cooling
3% less electricity than the median of 6 comparable 10 kW cooling only split system registrations (822 kWh a year) in the mixed zone. Uses less than 50% of them.
Across all 3,681 air conditioner registrations sold in Australia, it uses less than 82% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Fujitsu AOTH34CNTA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 494 | $158 | $1,581 |
| Mixed zone | 799 | $256 | $2,557 |
| Hot zone | 2,376 | $760 | $7,603 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTH30CNTA/ASTH30CNTA8.5 kW cooling651 kWh/yr | 4 | $208 | |
| Daikin RKM85WVMA / FTKM85WVMA8.5 kW cooling718 kWh/yr | 3 | $230 | |
| Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD29 kW cooling771 kWh/yr | 3 | $247 | |
| Mitsubishi Electric MUY-GY90VFD/MSY-GY90VFD29 kW cooling771 kWh/yr | 3 | $247 |
Air conditioners similar to the Fujitsu AOTH34CNTA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RKM95WVMA / FTKM95WVMA9.5 kW cooling844 kWh/yr | 3 | $270 | |
| Daikin RKM95P2VMA / FTKM95P2VMA9.4 kW cooling944 kWh/yr | 2.5 | $302 | |
| Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD2 Series9 kW cooling771 kWh/yr | 3 | $247 | |
| Mitsubishi Electric MUY-GY90VFD2/MSY-GY90VFD9 kW cooling771 kWh/yr | 3 | $247 |
Other Fujitsu models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTG34CMTA/ASTG34CMTA9.4 kW cooling904 kWh/yr | 2.5 | $289 | |
| Fujitsu AOTH30CNTA/ASTH30CNTA8.5 kW cooling651 kWh/yr | 4 | $208 |
Compare AOTH34CNTA/ASTH34CNTA with another model
Fujitsu AOTH34CNTA specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 9.50 kW
- Cooling power input
- 2.83 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.50
- COP, full load (tested)
- β
- Rated AEER
- 3.35
- Rated ACOP
- β
- Standby power (PIA)
- 0.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 65 dB(A)
- Outdoor sound power
- 67 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Fujitsu AOTH34CNTA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,030 | β |
| Coldresidential | residential | 3.5 | β | 494 | β |
| Mixedcommercial | commercial | β | β | 1,348 | β |
| Mixedresidential | residential | 3.5 | β | 799 | β |
| Hotcommercial | commercial | β | β | 3,118 | β |
| Hotresidential | residential | 3.5 | β | 2,376 | β |
Part-load test points (9 values)
- c__t1_half_cap_power_rated
- 900 W
- c__t1_have_min_cap_results
- No
- c__low_temp_full_cap_power_rated
- 2586.62 W
- c__low_temp_half_cap_power_rated
- 774 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4850 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 10231.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 5090 W
Australian GEMS registration details
- Registration number
- AAC7623
- GEMS registration id
- 155211
- Status
- approved, available (self-reported)
- Registration expires
- 8 July 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.