c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
3,141 kWh
1,065 cooling + 2,076 heating
Estimated running cost
$1,005 / year
$84 / month Β· $10,051 over 10 years
Capacity
14 kW cooling
17 kW heating

11% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 83% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Kaden KDI-14.0S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,355$2,034$20,336
Mixed zone 3,141$1,005$10,051
Hot zone 3,333$1,067$10,666

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819
Carrier 38QSH125D8S-1/42QSH125D8S-112.8 kW heating12.4 kW cooling2,581 kWh/yr3.5$826
Kaden KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828

Air conditioners similar to the Kaden KDI-14.0S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr3.5$923
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling2,996 kWh/yr3.5$959
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling2,951 kWh/yr3.5$944
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling2,996 kWh/yr3.5$959
Pioneer International VPC-48A1/VPE-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr3.5$938
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr3.5$942
Pioneer International VPC-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956

Compare KDI-14.0S with another model

Kaden KDI-14.0S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
3.90 kW
Rated heating capacity (7 Β°C)
17.00 kW
Heating power input
4.18 kW
EER, full load (tested)
3.55
COP, full load (tested)
4.00
Rated AEER
3.56
Rated ACOP
4.04
Standby power (PIA)
9.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KDI-14.0S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8501,766
Coldresidential4.02.06725,683
Mixedcommercial––1,364905
Mixedresidential3.53.01,0652,076
Hotcommercial––3,457191
Hotresidential4.53.53,034299
Part-load test points (23 values)
c__t1_min_cap_power_rated
1080 W
h__h1_min_cap_power_rated
705 W
h__h2_ext_cap_power_rated
5105 W
c__t1_half_cap_power_rated
1880 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1510 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3620 W
h__h2_ext_cap_heat_cap_rated
15300 W
h__h1_half_cap_heat_cap_rated
8140 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
705 W
c__t1_min_cap_cooling_cap_rated
4200 W
c__low_temp_half_cap_power_rated
1188 W
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
5090 W
c__low_temp_half_cap_cooling_cap_rated
7820 W

Australian GEMS registration details

Registration number
AAC9222
GEMS registration id
171580
Status
approved, available (self-reported)
Registration expires
11 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com/global. How the derived figures are calculated.