c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
1,595 kWh
632 cooling + 963 heating
Estimated running cost
$510 / year
$43 / month Β· $5,104 over 10 years
Capacity
7 kW cooling
7 kW heating

About the same electricity as the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 51% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Kogan KASHSAC70TD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,069$982$9,821
Mixed zone 1,595$510$5,104
Hot zone 1,982$634$6,342

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr4.5$410
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr4.5$439
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr3$448

Air conditioners similar to the Kogan KASHSAC70TD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG70B/CASN-XG70B7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Midea MFAG70VB-W/MFAG70VB-N7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Hitachi RAC-VJ70PHAT/RAK-VJ70PHAT8 kW heating7 kW cooling1,453 kWh/yr4$465
Kaden KSI-7.07.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Carrier 38QRF070N8/42QRF070N87.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling1,509 kWh/yr3.5$483

Compare KASHSAC70TD with another model

Kogan KASHSAC70TD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
2.01 kW
Rated heating capacity (7 Β°C)
7.00 kW
Heating power input
2.09 kW
EER, full load (tested)
3.41
COP, full load (tested)
3.30
Rated AEER
3.45
Rated ACOP
3.32
Standby power (PIA)
4.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
52.7 dB(A)
Outdoor sound power
63.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kogan KASHSAC70TD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––787822
Coldresidential3.01.54022,667
Mixedcommercial––1,041418
Mixedresidential3.02.5632963
Hotcommercial––2,39288
Hotresidential3.03.01,845137
Part-load test points (18 values)
c__t1_half_cap_power_rated
740 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
680 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2300 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
3500 W
h__h2_full_cap_heat_cap_rated
6000 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
1837.14 W
c__low_temp_half_cap_power_rated
600 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
7539 W
c__low_temp_half_cap_cooling_cap_rated
3500 W

Other model numbers on registration AAC8263

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8263
GEMS registration id
161990
Status
approved, available (self-reported)
Registration expires
23 May 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
KASHSAC70T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.