c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
597 kWh
165 cooling + 432 heating
Estimated running cost
$191 / year
$16 / month Β· $1,910 over 10 years
Capacity
2.1 kW cooling
2.1 kW heating

42% more electricity than the median of 62 comparable 2 kW reverse cycle split system registrations (422 kWh a year) in the mixed zone. Uses less than 0% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 90% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Maxa LZL21 ODU running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 920$294$2,944
Mixed zone 597$191$1,910
Hot zone 673$215$2,154

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling367 kWh/yr5$117
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling370 kWh/yr5$118
Kaden KSI062.3 kW heating2 kW cooling370 kWh/yr5$118
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling370 kWh/yr5$118
Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling378 kWh/yr5$121

Air conditioners similar to the Maxa LZL21 ODU

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier Carrier Ambi2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Hyundai HYSSSAC21TC2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Midea MFEZ20VA-W/MFEZ20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Carrier 38QUH020N8L/42QCE020N8F2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Midea MFEF20VA-W/MFEF20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
TCL TAC-08CHSD/TPH21ITU2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
TCL TAC-08CHSD/*ITU2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Hyundai HYSSSAC21T*2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137

Compare LZL21 ODU / LZL21 IDU with another model

Maxa LZL21 ODU specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.15 kW
Cooling power input
0.52 kW
Rated heating capacity (7 Β°C)
2.10 kW
Heating power input
0.44 kW
EER, full load (tested)
4.23
COP, full load (tested)
4.85
Rated AEER
4.04
Rated ACOP
4.64
Standby power (PIA)
3.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
49.3 dB(A)
Outdoor sound power
63.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Maxa LZL21 ODU zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––168391
Coldresidential3.52.5107813
Mixedcommercial––238295
Mixedresidential3.53.0165432
Hotcommercial––554203
Hotresidential4.53.0456217
Part-load test points (18 values)
h__h2_ext_cap_power_rated
855 W
c__t1_half_cap_power_rated
220 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2800 W
h__h1_half_cap_heat_cap_rated
1000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
160 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1150 W

Australian GEMS registration details

Registration number
AAC9541
GEMS registration id
174074
Status
approved, available (self-reported)
Registration expires
5 November 2030
Registered for sale in
Australia
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.