c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
428 kWh
165 cooling + 263 heating
Estimated running cost
$137 / year
$11 / month Β· $1,370 over 10 years
Capacity
2.1 kW cooling
2.1 kW heating

1% more electricity than the median of 61 comparable 2 kW reverse cycle split system registrations (422 kWh a year) in the mixed zone. Uses less than 44% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 96% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TCL TAC-08CHSD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 749$240$2,397
Mixed zone 428$137$1,370
Hot zone 503$161$1,610

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling367 kWh/yr5$117
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling370 kWh/yr5$118
Kaden KSI062.3 kW heating2 kW cooling370 kWh/yr5$118
Carrier 38QRG020N8/42QRG020N82.2 kW heating2 kW cooling378 kWh/yr5$121
Carrier 38QAG020N8/42QAG020N82.2 kW heating2 kW cooling378 kWh/yr5$121

Air conditioners similar to the TCL TAC-08CHSD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC21TA2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Carrier 38QUH020N8L/42QCE020N8F2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Midea MFEZ20VA-W/MFEZ20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Carrier 38QCE020N8/42QCE020N82.5 kW heating2.1 kW cooling391 kWh/yr5$125
Maxa LZL21 ODU / LZL21 IDU2.1 kW heating2.1 kW cooling597 kWh/yr3.5$191
Hyundai HYSSSAC21TC2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Midea MFEF20VA-W/MFEF20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling380 kWh/yr5.5$122

Compare TAC-08CHSD/TPH21ITU with another model

TCL TAC-08CHSD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.15 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
2.10 kW
Heating power input
–
EER, full load (tested)
4.23
COP, full load (tested)
4.85
Rated AEER
4.04
Rated ACOP
4.64
Standby power (PIA)
3.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
49.3 dB(A)
Outdoor sound power
63.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-08CHSD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––168220
Coldresidential3.52.5107642
Mixedcommercial––238124
Mixedresidential3.53.0165263
Hotcommercial––55431
Hotresidential4.53.045647
Part-load test points (18 values)
h__h2_ext_cap_power_rated
855 W
c__t1_half_cap_power_rated
220 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2800 W
h__h1_half_cap_heat_cap_rated
1000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
160 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1150 W

Other model numbers on registration AAC8809

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8809
GEMS registration id
–
Status
approved
Registration expires
29 April 2030
Registered for sale in
Australia, New Zealand
Family
TAC-08CHSD/*ITU
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8