c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
2,607 kWh
926 cooling + 1,681 heating
Estimated running cost
$834 / year
$70 / month Β· $8,342 over 10 years
Capacity
12.5 kW cooling
13 kW heating

12% less electricity than the median of 76 comparable 12.5 kW reverse cycle split system registrations (2,979 kWh a year) in the mixed zone. Uses less than 87% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mdv running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,013$1,604$16,042
Mixed zone 2,607$834$8,342
Hot zone 2,831$906$9,059

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803

Air conditioners similar to the Mdv

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling2,787 kWh/yr3$892
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Gree GUD125W1/NhC-S / GUD125T1/C-S14 kW heating12.5 kW cooling2,856 kWh/yr3.5$914
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling2,815 kWh/yr3$901
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr4$834
Daikin RZAV125F2Y1 / FCA125CVMA15 kW heating12.5 kW cooling2,623 kWh/yr3.5$839

Compare C-UV-125N8-QC3W / CSV-125N8-QC3W with another model

Mdv specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.39 kW
Rated heating capacity (7 Β°C)
13.00 kW
Heating power input
3.42 kW
EER, full load (tested)
3.69
COP, full load (tested)
3.81
Rated AEER
3.65
Rated ACOP
3.76
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.5 dB(A)
Outdoor sound power
70.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mdv zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5531,378
Coldresidential4.02.05834,430
Mixedcommercial––1,093721
Mixedresidential4.02.59261,681
Hotcommercial––2,629156
Hotresidential4.53.02,586245
Part-load test points (25 values)
c__t1_min_cap_power_rated
725 W
h__h1_min_cap_power_rated
540 W
h__h2_ext_cap_power_rated
5780 W
c__t1_half_cap_power_rated
1655 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1240 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2760 W
h__h2_ext_cap_heat_cap_rated
14800 W
h__h1_half_cap_heat_cap_rated
6155 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
460 W
c__t1_min_cap_cooling_cap_rated
3760 W
c__low_temp_full_cap_power_rated
3098.46 W
c__low_temp_half_cap_power_rated
935 W
c__t1_half_cap_cooling_cap_rated
5950 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3720 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6060 W

Australian GEMS registration details

Registration number
AAC7207
GEMS registration id
151230
Status
approved, available (self-reported)
Registration expires
13 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.