c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
2,509 kWh
1,070 cooling + 1,439 heating
Estimated running cost
$803 / year
$67 / month Β· $8,029 over 10 years
Capacity
12.5 kW cooling
12.5 kW heating

16% less electricity than the median of 76 comparable 12.5 kW reverse cycle split system registrations (2,979 kWh a year) in the mixed zone. Uses less than 95% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 43% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-125PZ4R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,631$1,482$14,819
Mixed zone 2,509$803$8,029
Hot zone 3,254$1,041$10,413

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766

Air conditioners similar to the Panasonic U-125PZ4R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr4$834
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling2,787 kWh/yr3$892
Braemar KCHA125D1B/KBHA125D1S14 kW heating12.5 kW cooling2,877 kWh/yr3.5$921
Gree GUD125W1/NhC-S / GUD125T1/C-S14 kW heating12.5 kW cooling2,856 kWh/yr3.5$914
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling2,815 kWh/yr3$901
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling2,607 kWh/yr4$834
Daikin RZAV125F2V1 / FCA125CVMA15 kW heating12.5 kW cooling2,623 kWh/yr3.5$839
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629

Compare U-125PZ4R8 / S-1014PU3E with another model

Panasonic U-125PZ4R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.49 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
2.82 kW
EER, full load (tested)
3.80
COP, full load (tested)
4.66
Rated AEER
3.52
Rated ACOP
4.33
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-125PZ4R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3571,249
Coldresidential3.02.56783,953
Mixedcommercial––1,756647
Mixedresidential3.03.01,0701,439
Hotcommercial––3,898156
Hotresidential3.54.03,019235
Part-load test points (22 values)
h__h1_min_cap_power_rated
560 W
h__h2_ext_cap_power_rated
4000 W
c__t1_half_cap_power_rated
1150 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1050 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3100 W
h__h2_ext_cap_heat_cap_rated
11500 W
h__h1_half_cap_heat_cap_rated
6250 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
490 W
c__low_temp_half_cap_power_rated
920 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3000 W
c__low_temp_half_cap_cooling_cap_rated
6350 W

Australian GEMS registration details

Registration number
AAC9321
GEMS registration id
171995
Status
approved, available (self-reported)
Registration expires
27 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.