Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Midea MFAB-70WD/MFAB-70ND Air Conditioner
Midea MFAB-70WD/MFAB-70ND is a 7 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8870).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 1,510 kWh
- 552 cooling + 958 heating
- Estimated running cost
- $483 / year
- $40 / month Β· $4,832 over 10 years
- Capacity
- 7 kW cooling
- 7.5 kW heating
6% less electricity than the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 83% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 63% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Midea MFAB-70WD running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,949 | $944 | $9,437 |
| Mixed zone | 1,510 | $483 | $4,832 |
| Hot zone | 1,763 | $564 | $5,642 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr | 4.5 | $410 | |
| Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr | 3.5 | $419 | |
| Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr | 3.5 | $419 | |
| Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr | 4.5 | $439 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr | 3 | $448 |
Air conditioners similar to the Midea MFAB-70WD
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QRF070N8/42QRF070N87.5 kW heating7 kW cooling1,510 kWh/yr | 3.5 | $483 | |
| Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling1,510 kWh/yr | 3.5 | $483 | |
| Kaden KSI247.5 kW heating7 kW cooling1,518 kWh/yr | 3.5 | $486 | |
| Comfee CASG-XG70B/CASN-XG70B7.5 kW heating7 kW cooling1,510 kWh/yr | 3.5 | $483 | |
| Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling1,509 kWh/yr | 3.5 | $483 | |
| Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling1,510 kWh/yr | 3.5 | $483 | |
| Hitachi RAC-VJ70PHAT/RAK-VJ70PHAT8 kW heating7 kW cooling1,453 kWh/yr | 4 | $465 | |
| Kaden KSI-7.07.5 kW heating7 kW cooling1,510 kWh/yr | 3.5 | $483 |
Compare MFAB-70WD/MFAB-70ND with another model
Midea MFAB-70WD specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.00 kW
- Cooling power input
- 2.01 kW
- Rated heating capacity (7 Β°C)
- 7.50 kW
- Heating power input
- 1.95 kW
- EER, full load (tested)
- 3.47
- COP, full load (tested)
- 3.81
- Rated AEER
- 3.48
- Rated ACOP
- 3.85
- Standby power (PIA)
- 0.7 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 65.1 dB(A)
- Outdoor sound power
- 69.6 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFAB-70WD zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 462 | 810 |
| Coldresidential | residential | 4.0 | 2.0 | 346 | 2,603 |
| Mixedcommercial | commercial | β | β | 738 | 416 |
| Mixedresidential | residential | 3.5 | 2.5 | 552 | 958 |
| Hotcommercial | commercial | β | β | 1,939 | 82 |
| Hotresidential | residential | 4.0 | 3.0 | 1,632 | 131 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 760 W
- h__h1_min_cap_power_rated
- 470 W
- h__h2_ext_cap_power_rated
- 3010 W
- c__t1_half_cap_power_rated
- 875 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 715 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2380 W
- h__h2_ext_cap_heat_cap_rated
- 7600 W
- h__h1_half_cap_heat_cap_rated
- 3600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 485 W
- c__t1_min_cap_cooling_cap_rated
- 2910 W
- c__low_temp_half_cap_power_rated
- 615 W
- c__t1_half_cap_cooling_cap_rated
- 3660 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3180 W
- c__low_temp_half_cap_cooling_cap_rated
- 3775 W
Australian GEMS registration details
- Registration number
- AAC8870
- GEMS registration id
- 169421
- Status
- approved, available (self-reported)
- Registration expires
- 21 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.