Australia Β· costs in AUD

Cooling only split system air conditioner, wall hung
Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD Air Conditioner
Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD is a 6 kW cooling only split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9016).
- Energy rating (cooling)
- 4
- Annual electricity use
- 439 kWh
- Estimated running cost
- $140 / year
- $12 / month Β· $1,405 over 10 years
- Capacity
- 6 kW cooling
2% less electricity than the median of 10 comparable 6 kW cooling only split system registrations (449 kWh a year) in the mixed zone. Uses less than 70% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 96% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Mitsubishi Electric MUY-GW60VFD2 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 275 | $88 | $880 |
| Mixed zone | 439 | $140 | $1,405 |
| Hot zone | 1,278 | $409 | $4,090 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling393 kWh/yr | 4 | $126 | |
| Daikin RKM60WVMA / FTKM60WVMA6 kW cooling412 kWh/yr | 4.5 | $132 | |
| Daikin RKM60W2VMA / FTKM60W2VMA6 kW cooling415 kWh/yr | 4.5 | $133 |
Air conditioners similar to the Mitsubishi Electric MUY-GW60VFD2
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RKM60W2VMA / FTKM60W2VMA6 kW cooling415 kWh/yr | 4.5 | $133 | |
| Toshiba RAS-24E2ACVG-A/RAS-24E2KCVG-A6 kW cooling496 kWh/yr | 3.5 | $159 | |
| Hitachi RAC-DJ60PCAT/RAK-DJ60PCAT6 kW cooling446 kWh/yr | 4 | $143 | |
| Daikin RKM60WVMA / FTKM60WVMA6 kW cooling412 kWh/yr | 4.5 | $132 | |
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling393 kWh/yr | 4 | $126 |
Other Mitsubishi Electric models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric MUY-GW60VFD/MSY-GW60VFD6 kW cooling467 kWh/yr | 3.5 | $149 |
Compare MUY-GW60VFD2/MSY-GW60VFD with another model
Mitsubishi Electric MUY-GW60VFD2 specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.58 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.89
- COP, full load (tested)
- β
- Rated AEER
- 3.76
- Rated ACOP
- β
- Standby power (PIA)
- 5.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 60.3 dB(A)
- Outdoor sound power
- 62.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric MUY-GW60VFD2 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 523 | β |
| Coldresidential | residential | 4.0 | β | 275 | β |
| Mixedcommercial | commercial | β | β | 686 | β |
| Mixedresidential | residential | 4.0 | β | 439 | β |
| Hotcommercial | commercial | β | β | 1,646 | β |
| Hotresidential | residential | 4.5 | β | 1,278 | β |
Part-load test points (10 values)
- c__t1_min_cap_power_rated
- 225 W
- c__t1_half_cap_power_rated
- 515 W
- c__t1_have_min_cap_results
- Yes
- c__low_temp_min_cap_power_rated
- 215 W
- c__t1_min_cap_cooling_cap_rated
- 1450 W
- c__low_temp_half_cap_power_rated
- 450 W
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1910 W
- c__low_temp_half_cap_cooling_cap_rated
- 3360 W
Other model numbers on registration AAC9016
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC9016
- GEMS registration id
- 170340
- Status
- approved, available (self-reported)
- Registration expires
- 17 June 2030
- Registered for sale in
- Australia, New Zealand
- Family
- MUY-GW60VFD2/MSY-GW60VFD2 Series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.