c/kWh
Energy rating (cooling)
2
Heating: 3
Annual electricity use
2,134 kWh
940 cooling + 1,194 heating
Estimated running cost
$683 / year
$57 / month Β· $6,829 over 10 years
Capacity
9 kW cooling
10 kW heating

1% less electricity than the median of 20 comparable 10 kW reverse cycle registrations (2,161 kWh a year) in the mixed zone. Uses less than 70% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mitsubishi Electric PUMY-SP80VKMD3-A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,667$1,173$11,734
Mixed zone 2,134$683$6,829
Hot zone 2,829$905$9,053

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Haier 4U80S2PR1FA8 kW heating8 kW cooling1,652 kWh/yr3$529
Braemar NCHV08D14B8.8 kW heating8.2 kW cooling1,721 kWh/yr3.5$551
Rinnai MON4H09B9.3 kW heating9 kW cooling1,746 kWh/yr4$559
Rinnai MON4H09B9.6 kW heating9.2 kW cooling1,822 kWh/yr4$583
Daikin 4MXM80RVMA9.6 kW heating8 kW cooling1,846 kWh/yr2.5$591

Air conditioners similar to the Mitsubishi Electric PUMY-SP80VKMD3-A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B9.3 kW heating9 kW cooling1,746 kWh/yr4$559
Pioneer International TVN-090A110 kW heating9 kW cooling2,061 kWh/yr3$660
Rinnai MON4H09B1LA9.5 kW heating9 kW cooling1,834 kWh/yr4$587
Mitsubishi Heavy Industries FDCS90KXZEN1-W9 kW heating9 kW cooling2,164 kWh/yr2.5$692
Mitsubishi Heavy Industries FDC90KXZEN1-W9 kW heating9 kW cooling2,164 kWh/yr2.5$692
Hitachi RAM-G85N5HCE10 kW heating8.5 kW cooling1,984 kWh/yr3.5$635

Other Mitsubishi Electric models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUMY-SP80YKMD3-A-BS10 kW heating9 kW cooling2,134 kWh/yr2$683
Mitsubishi Electric PUMY-SP80YKMD3-A10 kW heating9 kW cooling2,134 kWh/yr2$683

Compare PUMY-SP80VKMD3-A with another model

Mitsubishi Electric PUMY-SP80VKMD3-A specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
10.00 kW
Heating power input
–
EER, full load (tested)
5.40
COP, full load (tested)
5.42
Rated AEER
4.34
Rated ACOP
4.87
Standby power (PIA)
24.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
67.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric PUMY-SP80VKMD3-A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3981,027
Coldresidential2.02.56363,031
Mixedcommercial––1,707566
Mixedresidential2.03.09401,194
Hotcommercial––3,545154
Hotresidential2.53.52,602227
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3450 W
c__t1_half_cap_power_rated
1160 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
920 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10520 W
h__h1_half_cap_heat_cap_rated
5000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4500 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC9842

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9842
GEMS registration id
–
Status
approved
Registration expires
10 February 2031
Registered for sale in
Australia, New Zealand
Family
PUMY-SP80VKMD3-A Series
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
19

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.