c/kWh
Energy rating (cooling)
2
Heating: 2.5
Annual electricity use
3,622 kWh
1,435 cooling + 2,187 heating
Estimated running cost
$1,159 / year
$97 / month Β· $11,590 over 10 years
Capacity
14 kW cooling
16 kW heating

2% more electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 39% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 28% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mitsubishi Electric running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,789$2,172$21,725
Mixed zone 3,622$1,159$11,590
Hot zone 4,412$1,412$14,118

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819
Carrier 38QSH125D8S-1/42QSH125D8S-112.8 kW heating12.4 kW cooling2,581 kWh/yr3.5$826
Kaden KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828

Air conditioners similar to the Mitsubishi Electric

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Pioneer International VPC-48A1/VPE-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Pioneer International VPC-48A1/CPE-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr3.5$923
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr3.5$942
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling2,951 kWh/yr3.5$944
Kaden KDI-14.015.5 kW heating14 kW cooling2,996 kWh/yr3.5$959
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr3.5$938
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916

Compare PUZ-ZM140VKA(2)-A/PEAD-M140JAA(D)2 Series with another model

Mitsubishi Electric specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.37 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.18 kW
EER, full load (tested)
3.50
COP, full load (tested)
4.03
Rated AEER
3.13
Rated ACOP
3.74
Standby power (PIA)
29.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9171,879
Coldresidential2.02.09225,867
Mixedcommercial––2,417993
Mixedresidential2.02.51,4352,187
Hotcommercial––5,361242
Hotresidential2.53.04,049363
Part-load test points (18 values)
h__h1_min_cap_power_rated
950 W
h__h2_ext_cap_power_rated
5500 W
c__t1_half_cap_power_rated
1460 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1620 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4400 W
h__h2_ext_cap_heat_cap_rated
14500 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC7879

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7879
GEMS registration id
157898
Status
approved, available (self-reported)
Registration expires
13 November 2028
Registered for sale in
Australia, New Zealand
Family
PUZ-ZM140VKA(2)-A/PEAD-M140JAA(D)2 Series
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11