Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Panasonic CU-RZ71AKR / S-71PK4R Air Conditioner
Panasonic CU-RZ71AKR / S-71PK4R is a 7.1 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9107).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 1,572 kWh
- 581 cooling + 991 heating
- Estimated running cost
- $503 / year
- $42 / month Β· $5,030 over 10 years
- Capacity
- 7.1 kW cooling
- 8 kW heating
2% less electricity than the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 59% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic CU-RZ71AKR running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,109 | $995 | $9,949 |
| Mixed zone | 1,572 | $503 | $5,030 |
| Hot zone | 1,855 | $594 | $5,936 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr | 4.5 | $410 | |
| Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr | 3.5 | $419 | |
| Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr | 3.5 | $419 | |
| Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr | 4.5 | $439 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr | 3 | $448 |
Air conditioners similar to the Panasonic CU-RZ71AKR
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar ACHV70D1S/ASHV70D1S7.8 kW heating7.1 kW cooling1,471 kWh/yr | 4.5 | $471 | |
| Kogan KASSSAC71H*7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Gree GWH24AVEXH-K6DNA1C/O / GWH24AVEXH-K6DNA1C/I7.8 kW heating7.1 kW cooling1,468 kWh/yr | 4 | $470 | |
| Gree GWH24ATEXF-K6DNA1E/O / GWH24AWEXF-K6DNA1E/I7.8 kW heating7.1 kW cooling1,471 kWh/yr | 4.5 | $471 | |
| Haier 1U71TPHRA / AS71TPHRA7.5 kW heating7.1 kW cooling1,458 kWh/yr | 3.5 | $467 | |
| Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling1,461 kWh/yr | 3.5 | $468 | |
| Kogan KASSSAC71HA7.5 kW heating7.1 kW cooling1,433 kWh/yr | 4 | $459 | |
| Kinghome KWH71ATBXB-K6DNA27.8 kW heating7.1 kW cooling1,471 kWh/yr | 4.5 | $471 |
Compare CU-RZ71AKR / S-71PK4R with another model
Panasonic CU-RZ71AKR specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.10 kW
- Cooling power input
- 2.06 kW
- Rated heating capacity (7 Β°C)
- 8.00 kW
- Heating power input
- 2.09 kW
- EER, full load (tested)
- 3.51
- COP, full load (tested)
- 3.89
- Rated AEER
- 3.41
- Rated ACOP
- 3.79
- Standby power (PIA)
- 6.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic CU-RZ71AKR zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 617 | 853 |
| Coldresidential | residential | 3.5 | 2.0 | 367 | 2,742 |
| Mixedcommercial | commercial | β | β | 855 | 434 |
| Mixedresidential | residential | 3.5 | 2.5 | 581 | 991 |
| Hotcommercial | commercial | β | β | 2,167 | 93 |
| Hotresidential | residential | 3.5 | 3.5 | 1,710 | 145 |
Part-load test points (21 values)
- c__t1_min_cap_power_rated
- 420 W
- h__h2_ext_cap_power_rated
- 2700 W
- c__t1_half_cap_power_rated
- 680 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 710 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7300 W
- h__h1_half_cap_heat_cap_rated
- 4000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 310 W
- c__t1_min_cap_cooling_cap_rated
- 1900 W
- c__low_temp_half_cap_power_rated
- 560 W
- c__t1_half_cap_cooling_cap_rated
- 3550 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2200 W
- c__low_temp_half_cap_cooling_cap_rated
- 3650 W
Australian GEMS registration details
- Registration number
- AAC9107
- GEMS registration id
- 170083
- Status
- approved, available (self-reported)
- Registration expires
- 21 July 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.