c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
2,367 kWh
858 cooling + 1,509 heating
Estimated running cost
$757 / year
$63 / month Β· $7,574 over 10 years
Capacity
10 kW cooling
12.5 kW heating

3% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 62% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 45% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,644$1,486$14,861
Mixed zone 2,367$757$7,574
Hot zone 2,684$859$8,589

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,884 kWh/yr3.5$603
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling1,936 kWh/yr3.5$620

Air conditioners similar to the Panasonic U-100PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Pioneer International VPC-36A110 kW heating10 kW cooling2,265 kWh/yr3$725
Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA2-UF11.2 kW heating10 kW cooling2,314 kWh/yr2.5$740
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr4$678
Mitsubishi Electric PUZ-ZM100VKA-A/PEA-M100HAA11.2 kW heating10 kW cooling2,314 kWh/yr2.5$740
Daikin RZAV100F2V1 / FBA100BVMA12 kW heating10 kW cooling2,230 kWh/yr3$714
Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling2,265 kWh/yr3$725
Toshiba RAV-GP1101AT8P-A/RAV-GM1101BTP-A11.2 kW heating10 kW cooling2,306 kWh/yr3.5$738
Daikin RZAV100F2Y1 / FBA100BVMA12 kW heating10 kW cooling2,230 kWh/yr3$714

Compare U-100PZH3R5 / S-100PE4R with another model

Panasonic U-100PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.64 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
3.13 kW
EER, full load (tested)
3.72
COP, full load (tested)
4.01
Rated AEER
3.72
Rated ACOP
3.93
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1121,266
Coldresidential3.02.05534,091
Mixedcommercial––1,414656
Mixedresidential3.03.08581,509
Hotcommercial––3,219151
Hotresidential3.53.52,453231
Part-load test points (22 values)
h__h1_min_cap_power_rated
650 W
h__h2_ext_cap_power_rated
4400 W
c__t1_half_cap_power_rated
1020 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1220 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3750 W
h__h2_ext_cap_heat_cap_rated
12200 W
h__h1_half_cap_heat_cap_rated
6250 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
490 W
c__low_temp_half_cap_power_rated
880 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3400 W
c__low_temp_half_cap_cooling_cap_rated
5450 W

Australian GEMS registration details

Registration number
AAC9333
GEMS registration id
171975
Status
approved, available (self-reported)
Registration expires
28 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.