c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
1,974 kWh
852 cooling + 1,122 heating
Estimated running cost
$632 / year
$53 / month Β· $6,317 over 10 years
Capacity
9.5 kW cooling
9.5 kW heating

12% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 85% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,588$1,148$11,482
Mixed zone 1,974$632$6,317
Hot zone 2,594$830$8,301

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DN**E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Panasonic U-100PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Fujitsu AOTH34KMTD/ASTH34KMTD10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
Mitsubishi Heavy Industries DXC33ZRA-W / DXK33ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Daikin RXM95WVMA / FTXM95WVMA10.3 kW heating9.5 kW cooling2,352 kWh/yr3$753
Fujitsu AOTH34KNTA/ASTH34KNTA10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
Daikin RXM95P2VMA / FTXM95P2VMA10.3 kW heating9.4 kW cooling2,477 kWh/yr2.5$793
Carrier 38QHB090N8-1/42QHB090N8-110.1 kW heating9.1 kW cooling2,125 kWh/yr3.5$680

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-100PZH3R5/S-100PK3R9.5 kW heating9.5 kW cooling1,974 kWh/yr3$632

Compare U-100PZH3R8/S-100PK3R with another model

Panasonic U-100PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
2.91 kW
Rated heating capacity (7 Β°C)
9.50 kW
Heating power input
2.39 kW
EER, full load (tested)
3.46
COP, full load (tested)
4.05
Rated AEER
3.22
Rated ACOP
3.90
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1120 Γ— 302 Γ— 236 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,055939
Coldresidential3.02.55363,052
Mixedcommercial––1,372484
Mixedresidential3.03.08521,122
Hotcommercial––3,113113
Hotresidential3.54.02,422172
Part-load test points (22 values)
h__h1_min_cap_power_rated
550 W
h__h2_ext_cap_power_rated
4000 W
c__t1_half_cap_power_rated
1020 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
850 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3380 W
h__h2_ext_cap_heat_cap_rated
10000 W
h__h1_half_cap_heat_cap_rated
4800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
470 W
c__low_temp_half_cap_power_rated
830 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3200 W
c__low_temp_half_cap_cooling_cap_rated
5280 W

Australian GEMS registration details

Registration number
AAC9615
GEMS registration id
174317
Status
approved, available (self-reported)
Registration expires
15 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.