Australia Β· costs in AUD

Reverse cycle split system air conditioner, floor / ceiling
Panasonic U-140PZ3R5/S-1014PT3E Air Conditioner
Panasonic U-140PZ3R5/S-1014PT3E is a 13.6 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9777).
- Energy rating (cooling)
- 2.5
- Heating: 2.5
- Annual electricity use
- 3,112 kWh
- 1,272 cooling + 1,840 heating
- Estimated running cost
- $996 / year
- $83 / month Β· $9,958 over 10 years
- Capacity
- 13.6 kW cooling
- 14 kW heating
9% less electricity than the median of 59 comparable 14 kW reverse cycle split system registrations (3,413 kWh a year) in the mixed zone. Uses less than 70% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-140PZ3R5 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,990 | $1,917 | $19,168 |
| Mixed zone | 3,112 | $996 | $9,958 |
| Hot zone | 3,928 | $1,257 | $12,570 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 13.6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr | 2.5 | $629 | |
| Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr | 2.5 | $766 | |
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr | 3 | $803 | |
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr | 3 | $803 | |
| Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr | 4 | $834 |
Air conditioners similar to the Panasonic U-140PZ3R5
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Samsung Electronics AC140HCADKG/SA / AC140HE6DKG/SA16 kW heating13.6 kW cooling3,647 kWh/yr | 2.5 | $1,167 | |
| Samsung Electronics AC140TXAPKG/SA / AC140TN4PKG/SA16 kW heating13.6 kW cooling3,692 kWh/yr | 2.5 | $1,181 | |
| Braemar KCHV140D1B/KBHV140D1S16 kW heating13.6 kW cooling3,826 kWh/yr | 3 | $1,224 | |
| LG UU140WR3 U30/UTN140MA NA015.5 kW heating13.6 kW cooling3,779 kWh/yr | 2.5 | $1,209 | |
| Braemar KCHV140D1B/KBHV140D1S16 kW heating13.6 kW cooling3,826 kWh/yr | 3 | $1,224 | |
| Hisense AUW-140U4RN1/ AUC-140U4RKC115 kW heating13.5 kW cooling4,137 kWh/yr | 2.5 | $1,324 | |
| Mitsubishi Electric PUZ-ZM140VKA-A/PLA-M140EA2-A16 kW heating13.5 kW cooling3,561 kWh/yr | 2.5 | $1,140 | |
| Mitsubishi Electric PUZ-ZM140VKA2-A/PLA-M140EA-A16 kW heating13.5 kW cooling3,561 kWh/yr | 2.5 | $1,140 |
Compare U-140PZ3R5/S-1014PT3E with another model
Panasonic U-140PZ3R5 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Floor / ceiling
- Rated cooling capacity (35 Β°C)
- 13.60 kW
- Cooling power input
- 4.32 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.78 kW
- EER, full load (tested)
- 3.07
- COP, full load (tested)
- 3.66
- Rated AEER
- 3.10
- Rated ACOP
- 3.64
- Standby power (PIA)
- 20.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1590 Γ 235 Γ 690 mm
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-140PZ3R5 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,563 | 1,549 |
| Coldresidential | residential | 2.5 | 2.0 | 806 | 5,184 |
| Mixedcommercial | commercial | β | β | 2,025 | 771 |
| Mixedresidential | residential | 2.5 | 2.5 | 1,272 | 1,840 |
| Hotcommercial | commercial | β | β | 4,729 | 177 |
| Hotresidential | residential | 3.0 | 3.5 | 3,655 | 273 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 567 W
- h__h2_ext_cap_power_rated
- 4630 W
- c__t1_half_cap_power_rated
- 1480 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1380 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 11700 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 540 W
- c__low_temp_half_cap_power_rated
- 1250 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 6800 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3800 W
- c__low_temp_half_cap_cooling_cap_rated
- 7400 W
Australian GEMS registration details
- Registration number
- AAC9777
- GEMS registration id
- 175920
- Status
- approved, available (self-reported)
- Registration expires
- 11 February 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.