c/kWh
Energy rating (cooling)
2.5
Heating: 2.5
Annual electricity use
3,103 kWh
1,275 cooling + 1,828 heating
Estimated running cost
$993 / year
$83 / month Β· $9,930 over 10 years
Capacity
13.6 kW cooling
14 kW heating

9% less electricity than the median of 59 comparable 14 kW reverse cycle split system registrations (3,413 kWh a year) in the mixed zone. Uses less than 73% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-140PZ4R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,971$1,911$19,107
Mixed zone 3,103$993$9,930
Hot zone 3,931$1,258$12,579

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13.6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr4$834

Air conditioners similar to the Panasonic U-140PZ4R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDCA140VSX-W / FDE140VH16 kW heating14 kW cooling3,449 kWh/yr2.5$1,104
Mitsubishi Heavy Industries FDC140VSX-W / FDE140VH16 kW heating14 kW cooling3,449 kWh/yr2.5$1,104
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766
Samsung Electronics AC140HCADKG/SA / AC140HE6DKG/SA16 kW heating13.6 kW cooling3,647 kWh/yr2.5$1,167
Samsung Electronics AC140TXAPKG/SA / AC140TN4PKG/SA16 kW heating13.6 kW cooling3,692 kWh/yr2.5$1,181
Braemar KCHV140D1B/KBHV140D1S16 kW heating13.6 kW cooling3,826 kWh/yr3$1,224
LG UU140WR3 U30/UTN140MA NA015.5 kW heating13.6 kW cooling3,779 kWh/yr2.5$1,209

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-140PZ4R5 / S-1014PT3E14 kW heating13.6 kW cooling3,103 kWh/yr2.5$993

Compare U-140PZ4R8 / S-1014PT3E with another model

Panasonic U-140PZ4R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
13.60 kW
Cooling power input
4.32 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.78 kW
EER, full load (tested)
3.36
COP, full load (tested)
4.02
Rated AEER
3.10
Rated ACOP
3.64
Standby power (PIA)
20.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZ4R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5681,531
Coldresidential2.52.08085,163
Mixedcommercial––2,031757
Mixedresidential2.52.51,2751,828
Hotcommercial––4,738174
Hotresidential3.03.53,662269
Part-load test points (22 values)
h__h1_min_cap_power_rated
530 W
h__h2_ext_cap_power_rated
4630 W
c__t1_half_cap_power_rated
1480 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1380 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3100 W
h__h2_ext_cap_heat_cap_rated
11700 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
490 W
c__low_temp_half_cap_power_rated
1250 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3400 W
c__low_temp_half_cap_cooling_cap_rated
7400 W

Australian GEMS registration details

Registration number
AAC9332
GEMS registration id
172005
Status
approved, available (self-reported)
Registration expires
28 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.