c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
3,287 kWh
1,245 cooling + 2,042 heating
Estimated running cost
$1,052 / year
$88 / month Β· $10,518 over 10 years
Capacity
14 kW cooling
16 kW heating

7% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 76% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 32% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-140PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,233$1,995$19,946
Mixed zone 3,287$1,052$10,518
Hot zone 3,906$1,250$12,499

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819
Carrier 38QSH125D8S-1/42QSH125D8S-112.8 kW heating12.4 kW cooling2,581 kWh/yr3.5$826
Kaden KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828

Air conditioners similar to the Panasonic U-140PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Pioneer International VPC-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr3.5$923
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling2,951 kWh/yr3.5$944
Carrier 38QSV140N8E/42QSV140N8H15.5 kW heating14 kW cooling2,996 kWh/yr3.5$959
Pioneer International VPC-48A1/VPE-48A114 kW heating14 kW cooling2,988 kWh/yr3.5$956
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr3.5$938
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr3.5$942
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916

Compare U-140PZH3R5 / S-140PE4R with another model

Panasonic U-140PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.15 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
3.90 kW
EER, full load (tested)
3.52
COP, full load (tested)
4.24
Rated AEER
3.32
Rated ACOP
4.04
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5511,743
Coldresidential3.02.07915,442
Mixedcommercial––2,002920
Mixedresidential3.02.51,2452,042
Hotcommercial––4,654212
Hotresidential3.53.03,583323
Part-load test points (22 values)
h__h1_min_cap_power_rated
700 W
h__h2_ext_cap_power_rated
5300 W
c__t1_half_cap_power_rated
1430 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1560 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3300 W
h__h2_ext_cap_heat_cap_rated
15200 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
520 W
c__low_temp_half_cap_power_rated
1200 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3700 W
c__low_temp_half_cap_cooling_cap_rated
7450 W

Australian GEMS registration details

Registration number
AAC9334
GEMS registration id
171977
Status
approved, available (self-reported)
Registration expires
28 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.