c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
3,041 kWh
1,164 cooling + 1,877 heating
Estimated running cost
$973 / year
$81 / month Β· $9,731 over 10 years
Capacity
14 kW cooling
16 kW heating

11% less electricity than the median of 59 comparable 14 kW reverse cycle split system registrations (3,413 kWh a year) in the mixed zone. Uses less than 76% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-140PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,966$1,909$19,091
Mixed zone 3,041$973$9,731
Hot zone 3,667$1,173$11,734

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr4$834

Air conditioners similar to the Panasonic U-140PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RZAV140F2V1 / FCA140CVMA16.5 kW heating14 kW cooling2,969 kWh/yr3.5$950
Mdv C-UV-140N8-QC3W / CSV-140N8-QC3W14.5 kW heating14 kW cooling2,928 kWh/yr3.5$937
Kaden KDI48 / KCI4814.5 kW heating14 kW cooling2,928 kWh/yr3.5$937
Hitachi PAS-6.0UFASNQ1 / PCI-6.0UFA1NQ16 kW heating14 kW cooling3,290 kWh/yr3$1,053
Toshiba RAV-GM1601AT8P-A/RAV-GM1601UTP-A16 kW heating14 kW cooling3,400 kWh/yr3$1,088
Daikin RZAV140F2Y1 / FCA140CVMA16.5 kW heating14 kW cooling2,969 kWh/yr3.5$950
Hitachi PAS-6.0UFASMQ1 / PCI-6.0UFA1NQ16 kW heating14 kW cooling3,499 kWh/yr3$1,120
Toshiba RAV-GM1601ATP-A/RAV-GM1601UTP-A16 kW heating14 kW cooling3,401 kWh/yr3$1,088

Compare U-140PZH3R8/S-1014PU3E with another model

Panasonic U-140PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.11 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
3.72 kW
EER, full load (tested)
3.30
COP, full load (tested)
4.11
Rated AEER
3.37
Rated ACOP
4.25
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
840 Γ— 319 Γ— 840 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4141,582
Coldresidential3.52.57315,235
Mixedcommercial––1,847789
Mixedresidential3.03.01,1641,877
Hotcommercial––4,383172
Hotresidential3.54.03,395272
Part-load test points (22 values)
h__h1_min_cap_power_rated
548 W
h__h2_ext_cap_power_rated
6200 W
c__t1_half_cap_power_rated
1360 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1490 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3300 W
h__h2_ext_cap_heat_cap_rated
15500 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
454 W
c__low_temp_half_cap_power_rated
1120 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3700 W
c__low_temp_half_cap_cooling_cap_rated
7400 W

Australian GEMS registration details

Registration number
AAC9622
GEMS registration id
174367
Status
approved, available (self-reported)
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.