c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
3,806 kWh
1,398 cooling + 2,408 heating
Estimated running cost
$1,218 / year
$101 / month Β· $12,179 over 10 years
Capacity
16.3 kW cooling
16 kW heating

7% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (4,079 kWh a year) in the mixed zone. Uses less than 85% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 25% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Pioneer International VPC-60D1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,683$2,459$24,586
Mixed zone 3,806$1,218$12,179
Hot zone 4,454$1,425$14,253

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 16.3 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
AirSmart IES-700-AC15.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling3,506 kWh/yr2.5$1,122
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling3,506 kWh/yr2.5$1,122
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling3,533 kWh/yr3$1,131

Air conditioners similar to the Pioneer International VPC-60D1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar KCDB195D1B/KGDB195A1S17.9 kW heating16.5 kW cooling3,994 kWh/yr2.5$1,278
APAC S015OVR3SA / S015ILR1SA-FR14.2 kW heating16 kW cooling4,561 kWh/yr1.5$1,460
APAC S015OVR3SA / S015IVR3SA-TR14.2 kW heating16 kW cooling4,561 kWh/yr1.5$1,460
TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling3,695 kWh/yr3$1,182
Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling3,673 kWh/yr3$1,175
Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,677 kWh/yr3$1,177
Tosot TFH60DEXL-S6DND7D/O / TFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,677 kWh/yr3$1,177
Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,673 kWh/yr3$1,175

Compare VPC-60D1/VPE-60A1/CPE-60A1 with another model

Pioneer International VPC-60D1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.29 kW
Cooling power input
4.63 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.65 kW
EER, full load (tested)
3.61
COP, full load (tested)
3.50
Rated AEER
3.51
Rated ACOP
3.44
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
M60
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
1390 Γ— 280 Γ— 715 mm
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Pioneer International VPC-60D1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9291,992
Coldresidential3.51.58746,809
Mixedcommercial––2,456985
Mixedresidential3.02.01,3982,408
Hotcommercial––5,563182
Hotresidential3.53.04,161293
Part-load test points (18 values)
c__t1_half_cap_power_rated
1545 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1472 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
5088 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
7590 W
h__h2_full_cap_heat_cap_rated
11798 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
4231.82 W
c__low_temp_half_cap_power_rated
1412.13 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
8192 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
17544.329999999998 W
c__low_temp_half_cap_cooling_cap_rated
8822.784 W

Other model numbers on registration AAC7409

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7409
GEMS registration id
152924
Status
approved, available (self-reported)
Registration expires
4 April 2028
Registered for sale in
Australia, New Zealand
Family
VPC-60D1/VPE-60A1/CPE-60A1
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.