Australia Β· costs in AUD

Reverse cycle split system air conditioner
Hisense AUW-140U4RH1/AUD-140UX4RSH1 Air Conditioner
Hisense AUW-140U4RH1/AUD-140UX4RSH1 is a 14.5 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8071).
- Energy rating (cooling)
- 3
- Heating: 2.5
- Annual electricity use
- 3,533 kWh
- 1,316 cooling + 2,217 heating
- Estimated running cost
- $1,131 / year
- $94 / month Β· $11,306 over 10 years
- Capacity
- 14.5 kW cooling
- 17 kW heating
About the same electricity as the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 51% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Hisense AUW-140U4RH1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,926 | $2,216 | $22,163 |
| Mixed zone | 3,533 | $1,131 | $11,306 |
| Hot zone | 4,182 | $1,338 | $13,382 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 14.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr | 5 | $799 | |
| Actron Air URC-125CS / LRE-125CS13.4 kW heating12.9 kW cooling2,656 kWh/yr | 3.5 | $850 | |
| Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr | 3.5 | $916 | |
| Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr | 3.5 | $923 | |
| Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr | 3.5 | $924 |
Air conditioners similar to the Hisense AUW-140U4RH1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KD4817 kW heating14.5 kW cooling4,310 kWh/yr | 2 | $1,379 | |
| Rinnai DONSR14Z72/ DINLR14Z7217 kW heating14.5 kW cooling3,769 kWh/yr | 4 | $1,206 | |
| Temperzone OSAT 145RLSFH / ISDT 145LY17 kW heating14.5 kW cooling3,763 kWh/yr | 2.5 | $1,204 | |
| Temperzone ISD 171LYX / OSA 171RLTFH14.9 kW heating14.5 kW cooling4,791 kWh/yr | 1.5 | $1,533 | |
| Actron Air CRV15AS / EVV15AS15.5 kW heating14.4 kW cooling4,132 kWh/yr | 2.5 | $1,322 | |
| Actron Air CRV15AS / EVV15AS - EXV SE15.5 kW heating14.4 kW cooling4,132 kWh/yr | 2.5 | $1,322 | |
| Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr | 3.5 | $916 | |
| Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr | 3.5 | $938 |
Compare AUW-140U4RH1/AUD-140UX4RSH1 with another model
Hisense AUW-140U4RH1 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 14.50 kW
- Cooling power input
- 4.08 kW
- Rated heating capacity (7 Β°C)
- 17.00 kW
- Heating power input
- 4.25 kW
- EER, full load (tested)
- 3.51
- COP, full load (tested)
- 4.21
- Rated AEER
- 3.52
- Rated ACOP
- 3.97
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hisense AUW-140U4RH1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,826 | 1,925 |
| Coldresidential | residential | 3.0 | 2.0 | 836 | 6,090 |
| Mixedcommercial | commercial | β | β | 2,306 | 987 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,316 | 2,217 |
| Hotcommercial | commercial | β | β | 5,158 | 210 |
| Hotresidential | residential | 3.0 | 3.0 | 3,854 | 328 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4570 W
- c__t1_half_cap_power_rated
- 1450 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1660 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 14000 W
- h__h1_half_cap_heat_cap_rated
- 8500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 3733.69 W
- c__low_temp_half_cap_power_rated
- 1325.3 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 7250 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 15616.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 7808.25 W
Australian GEMS registration details
- Registration number
- AAC8071
- GEMS registration id
- 159515
- Status
- approved, available (self-reported)
- Registration expires
- 26 February 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: global.hisense.com. How the derived figures are calculated.