c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
3,769 kWh
1,020 cooling + 2,749 heating
Estimated running cost
$1,206 / year
$101 / month Β· $12,061 over 10 years
Capacity
14.5 kW cooling
17 kW heating

6% more electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 27% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 26% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Rinnai DONSR14Z72 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,471$2,711$27,107
Mixed zone 3,769$1,206$12,061
Hot zone 3,353$1,073$10,730

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 14.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Actron Air URC-125CS / LRE-125CS13.4 kW heating12.9 kW cooling2,656 kWh/yr3.5$850
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr3.5$923
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr3.5$924

Air conditioners similar to the Rinnai DONSR14Z72

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KD4817 kW heating14.5 kW cooling4,310 kWh/yr2$1,379
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling3,533 kWh/yr3$1,131
Temperzone OSAT 145RLSFH / ISDT 145LY17 kW heating14.5 kW cooling3,763 kWh/yr2.5$1,204
Temperzone ISD 171LYX / OSA 171RLTFH14.9 kW heating14.5 kW cooling4,791 kWh/yr1.5$1,533
Actron Air CRV15AS / EVV15AS15.5 kW heating14.4 kW cooling4,132 kWh/yr2.5$1,322
Actron Air CRV15AS / EVV15AS - EXV SE15.5 kW heating14.4 kW cooling4,132 kWh/yr2.5$1,322
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling2,943 kWh/yr3.5$942

Compare DONSR14Z72/ DINLR14Z72 with another model

Rinnai DONSR14Z72 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.50 kW
Cooling power input
4.25 kW
Rated heating capacity (7 Β°C)
17.00 kW
Heating power input
4.50 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.90
Rated AEER
3.38
Rated ACOP
3.75
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1200 Γ— 380 Γ— 625 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai DONSR14Z72 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-8942,316
Coldresidential4.51.06477,824
Mixedcommercial––-9,8191,070
Mixedresidential4.01.51,0202,749
Hotcommercial––5,090209
Hotresidential4.53.03,016337
Part-load test points (25 values)
c__t1_min_cap_power_rated
1100 W
h__h1_min_cap_power_rated
560 W
h__h2_ext_cap_power_rated
4300 W
c__t1_half_cap_power_rated
1500 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1820 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2750 W
h__h2_ext_cap_heat_cap_rated
11500 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
500 W
c__t1_min_cap_cooling_cap_rated
2300 W
c__low_temp_full_cap_power_rated
3889.07 W
c__low_temp_half_cap_power_rated
1160 W
c__t1_half_cap_cooling_cap_rated
6900 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3480 W
c__low_temp_full_cap_cooling_cap_rated
15616.5 W
c__low_temp_half_cap_cooling_cap_rated
7500 W

Australian GEMS registration details

Registration number
AAC7745
GEMS registration id
156263
Status
approved, available (self-reported)
Registration expires
28 August 2028
Registered for sale in
Australia
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.