c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
1,518 kWh
625 cooling + 893 heating
Estimated running cost
$486 / year
$40 / month Β· $4,858 over 10 years
Capacity
7.2 kW cooling
7.3 kW heating

5% less electricity than the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 76% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 63% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TCL TAC-VX24HSV running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,833$907$9,066
Mixed zone 1,518$486$4,858
Hot zone 1,968$630$6,298

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr4.5$410
Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr4.5$439
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr3$448
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling1,404 kWh/yr4$449
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling1,421 kWh/yr2.5$455

Air conditioners similar to the TCL TAC-VX24HSV

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC72TC7.3 kW heating7.2 kW cooling1,518 kWh/yr3$486
Smart Lifestyle Australia SLA-72-CHSD7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Ers Tech ERS-AC72F017.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Domain ISR-72P-OUT/ISR-72P-IND7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Proma PRO-72ITPN7.3 kW heating7.2 kW cooling1,518 kWh/yr3$486
Bonaire CRC6911071/CRC69111717.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485
Hyundai HYSSSAC72T*7.3 kW heating7.2 kW cooling1,518 kWh/yr3$486
Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling1,516 kWh/yr3.5$485

Compare TAC-VX24HSV/UD with another model

TCL TAC-VX24HSV specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.20 kW
Cooling power input
2.09 kW
Rated heating capacity (7 Β°C)
7.30 kW
Heating power input
1.83 kW
EER, full load (tested)
3.35
COP, full load (tested)
4.04
Rated AEER
3.42
Rated ACOP
3.96
Standby power (PIA)
4.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.8 dB(A)
Outdoor sound power
65.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-VX24HSV zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––791768
Coldresidential3.52.03932,440
Mixedcommercial––1,038394
Mixedresidential3.03.0625893
Hotcommercial––2,40684
Hotresidential3.53.51,836132
Part-load test points (18 values)
h__h2_ext_cap_power_rated
2030 W
c__t1_half_cap_power_rated
695 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
660 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6400 W
h__h1_half_cap_heat_cap_rated
3680 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
560 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3760 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
3590 W

Other model numbers on registration AAC10354

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC10354
GEMS registration id
181230
Status
approved, available (self-reported)
Registration expires
3 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
TAC-VX24HSV/U*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.