Australia Β· costs in AUD

Reverse cycle split system air conditioner
TCL TCD160D1HWH-DVO(02) / TCD160D1HWH-DVI(02) Air Conditioner
TCL TCD160D1HWH-DVO(02) / TCD160D1HWH-DVI(02) is a 16 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9700).
- Energy rating (cooling)
- 3
- Heating: 2.5
- Annual electricity use
- 4,074 kWh
- 1,471 cooling + 2,603 heating
- Estimated running cost
- $1,304 / year
- $109 / month Β· $13,037 over 10 years
- Capacity
- 16 kW cooling
- 19.5 kW heating
About the same electricity as the median of 71 comparable 16 kW reverse cycle ducted split system registrations (4,079 kWh a year) in the mixed zone. Uses less than 54% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
TCL running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,939 | $2,540 | $25,405 |
| Mixed zone | 4,074 | $1,304 | $13,037 |
| Hot zone | 4,712 | $1,508 | $15,078 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| AirSmart IES-700-AC15.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling3,506 kWh/yr | 2.5 | $1,122 | |
| Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling3,506 kWh/yr | 2.5 | $1,122 | |
| Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling3,533 kWh/yr | 3 | $1,131 |
Air conditioners similar to the TCL
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling3,673 kWh/yr | 3 | $1,175 | |
| TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling3,695 kWh/yr | 3 | $1,182 | |
| Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,673 kWh/yr | 3 | $1,175 | |
| Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling3,677 kWh/yr | 3 | $1,177 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA18 kW heating16 kW cooling3,838 kWh/yr | 3 | $1,228 | |
| Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,677 kWh/yr | 3 | $1,177 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA218 kW heating16 kW cooling3,838 kWh/yr | 3 | $1,228 | |
| Tosot TFH60DEXL-S6DND7D/O / TFH60DEXL-S6DND7D/I18 kW heating16 kW cooling3,677 kWh/yr | 3 | $1,177 |
Compare TCD160D1HWH-DVO(02) / TCD160D1HWH-DVI(02) with another model
TCL specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 16.00 kW
- Cooling power input
- 4.86 kW
- Rated heating capacity (7 Β°C)
- 19.50 kW
- Heating power input
- 5.10 kW
- EER, full load (tested)
- 3.36
- COP, full load (tested)
- 3.81
- Rated AEER
- 3.28
- Rated ACOP
- 3.81
- Standby power (PIA)
- 6.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 74 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
TCL zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,784 | 2,232 |
| Coldresidential | residential | 3.0 | 2.0 | 927 | 7,012 |
| Mixedcommercial | commercial | β | β | 2,399 | 1,157 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,471 | 2,603 |
| Hotcommercial | commercial | β | β | 5,582 | 238 |
| Hotresidential | residential | 3.0 | 3.0 | 4,335 | 377 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 5800 W
- c__t1_half_cap_power_rated
- 1780 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1980 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 17300 W
- h__h1_half_cap_heat_cap_rated
- 9750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 1400 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 8000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 8000 W
Other model numbers on registration AAC9700
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC9700
- GEMS registration id
- 175384
- Status
- approved, available (self-reported)
- Registration expires
- 22 December 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- TCD160D1 series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.