c/kWh
Energy rating (cooling)
1.5
Annual electricity use
280 kWh
Estimated running cost
$90 / year
$7 / month Β· $896 over 10 years
Capacity
2.2 kW cooling

31% more electricity than the median of 21 comparable 2 kW cooling only window / wall registrations (214 kWh a year) in the mixed zone. Uses less than 5% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 98% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TECO TWW22CFAT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 185$59$592
Mixed zone 280$90$896
Hot zone 833$267$2,666

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Gree GJC07AK-K6NRNR1A2.2 kW cooling261 kWh/yr2$84
Westinghouse WH222.2 kW cooling261 kWh/yr2$84
TECO TWW22CFWDG2.2 kW cooling261 kWh/yr2$84
Kelvinator KWH22CRF2.2 kW cooling261 kWh/yr2$84
Gree GJC07AK-K6NRNB3C2.2 kW cooling261 kWh/yr2$84

Air conditioners similar to the TECO TWW22CFAT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GJC07AK-K6NRNG2A2.2 kW cooling261 kWh/yr2$84
Kogan KAVWACI22YA2.2 kW cooling282 kWh/yr1.5$90
Westinghouse WWH22CWA2.2 kW cooling261 kWh/yr2$84
Westinghouse WH222.2 kW cooling261 kWh/yr2$84
Kelvinator KWH22CRF2.2 kW cooling261 kWh/yr2$84
Kogan KAVWACI22Y*2.2 kW cooling282 kWh/yr1.5$90
Gree GJC07AK-K6NRNB3C2.2 kW cooling261 kWh/yr2$84

Other TECO models of similar capacity

ModelStarsEst. cost / yrCompare
TECO TWW22CFWDG2.2 kW cooling261 kWh/yr2$84

Compare TWW22CFAT with another model

TECO TWW22CFAT specifications

Type
Cooling only
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.20 kW
Cooling power input
0.65 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.39
COP, full load (tested)
–
Rated AEER
3.38
Rated ACOP
–
Standby power (PIA)
1.0 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
54.5 dB(A)
Outdoor sound power
61.8 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TWW22CFAT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––444–
Coldresidential1.5–185–
Mixedcommercial––541–
Mixedresidential1.5–280–
Hotcommercial––1,160–
Hotresidential1.5–833–
Part-load test points (3 values)
c__low_temp_full_cap_power_rated
600 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
2300 W

Australian GEMS registration details

Registration number
AAC7333
GEMS registration id
152524
Status
approved, available (self-reported)
Registration expires
1 March 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.