c/kWh
Energy rating (cooling)
1.5
Annual electricity use
284 kWh
Estimated running cost
$91 / year
$8 / month Β· $909 over 10 years
Capacity
2.3 kW cooling

13% less electricity than the median of 9 comparable 2.5 kW cooling only window / wall registrations (327 kWh a year) in the mixed zone. Uses less than 67% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 98% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WWH22CWC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 187$60$598
Mixed zone 284$91$909
Hot zone 843$270$2,698

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.3 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Kelvinator KWH22CRF2.2 kW cooling261 kWh/yr2$84
TECO TWW22CFWDG2.2 kW cooling261 kWh/yr2$84
Gree GJC07AK-K6NRNB3C2.2 kW cooling261 kWh/yr2$84
Westinghouse WWH22CWA2.2 kW cooling261 kWh/yr2$84
Gree GJC07AK-K6NRNG2A2.2 kW cooling261 kWh/yr2$84

Air conditioners similar to the Westinghouse WWH22CWC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KAVWACI22YB2.2 kW cooling282 kWh/yr1.5$90
Gree GJC07AK-K6NRNG2A2.2 kW cooling261 kWh/yr2$84
TECO TWW22CFWDG2.2 kW cooling261 kWh/yr2$84
Gree GJC07AK-K6NRNR1A2.2 kW cooling261 kWh/yr2$84
Kelvinator KWH22CRF2.2 kW cooling261 kWh/yr2$84
TECO TWW22CFAT2.2 kW cooling280 kWh/yr1.5$90
Kogan KAVWACI22YA2.2 kW cooling282 kWh/yr1.5$90

Other Westinghouse models of similar capacity

ModelStarsEst. cost / yrCompare
Westinghouse WWH22CWA2.2 kW cooling261 kWh/yr2$84

Compare WWH22CWC with another model

Westinghouse WWH22CWC specifications

Type
Cooling only
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.28 kW
Cooling power input
0.68 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.33
COP, full load (tested)
–
Rated AEER
3.34
Rated ACOP
–
Standby power (PIA)
0.7 W
Compressor
Fixed speed
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57.1 dB(A)
Outdoor sound power
64.3 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WWH22CWC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––433–
Coldresidential1.5–187–
Mixedcommercial––536–
Mixedresidential1.5–284–
Hotcommercial––1,160–
Hotresidential2.0–843–
Part-load test points (3 values)
c__low_temp_full_cap_power_rated
610 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
2400 W

Australian GEMS registration details

Registration number
AAC10185
GEMS registration id
179860
Status
approved, available (self-reported)
Registration expires
26 May 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.