Australia Β· costs in AUD

Reverse cycle packaged air conditioner
Temperzone OPA 2110RLTM1FDPQ Air Conditioner
Temperzone OPA 2110RLTM1FDPQ is a 193.8 kW reverse cycle ducted packaged air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7757).
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 61,463 kWh
- 24,813 cooling + 36,650 heating
- Estimated running cost
- $19,668 / year
- $1,639 / month Β· $196,682 over 10 years
- Capacity
- 193.8 kW cooling
- 194.7 kW heating
137% more electricity than the median of 54 comparable 80 kW and above reverse cycle ducted packaged registrations (25,969 kWh a year) in the mixed zone. Uses less than 4% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 0% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Temperzone OPA 2110RLTM1FDPQ running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 108,324 | $34,664 | $346,637 |
| Mixed zone | 61,463 | $19,668 | $196,682 |
| Hot zone | 79,129 | $25,321 | $253,213 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 193.8 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P170AHR3SA-CBR164.5 kW heating173.9 kW cooling22,808 kWh/yr | 1.5 | $7,299 | |
| APAC P170AHR3SA-CTR164.5 kW heating173.9 kW cooling22,808 kWh/yr | 1.5 | $7,299 | |
| Temperzone OPA2100RKTMDF-P186.7 kW heating178 kW cooling24,120 kWh/yr | 1.5 | $7,718 | |
| Temperzone FPA1700RKTMGQ-P182.1 kW heating182.9 kW cooling25,744 kWh/yr | 1 | $8,238 | |
| Actron Air PKV2000T180.4 kW heating187.5 kW cooling26,135 kWh/yr | 1 | $8,363 |
Air conditioners similar to the Temperzone OPA 2110RLTM1FDPQ
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| AIRSTAGE URT/EC/WP/MS/172/SK208 kW heating195 kW cooling60,813 kWh/yr | 1.5 | $19,460 | |
| AIRSTAGE URT-EC-WP-MS-172-SK208 kW heating195 kW cooling60,813 kWh/yr | 1.5 | $19,460 | |
| Actron Air PKV2000T180.4 kW heating187.5 kW cooling26,135 kWh/yr | 1 | $8,363 | |
| Carrier 50FC-180190 kW heating181 kW cooling65,242 kWh/yr | 1.5 | $20,877 | |
| APAC P200AHR3SA-CBR194.4 kW heating209 kW cooling26,144 kWh/yr | 1.5 | $8,366 | |
| APAC P200AHR3SA-194.4 kW heating209 kW cooling26,144 kWh/yr | 1.5 | $8,366 |
Other Temperzone models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA2000RKTMG-P186.1 kW heating183.6 kW cooling25,802 kWh/yr | 1 | $8,257 | |
| Temperzone FPA1700RKTMGQ-P182.1 kW heating182.9 kW cooling25,744 kWh/yr | 1 | $8,238 |
Compare OPA 2110RLTM1FDPQ with another model
Temperzone OPA 2110RLTM1FDPQ specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 193.81 kW
- Cooling power input
- 64.53 kW
- Rated heating capacity (7 Β°C)
- 194.71 kW
- Heating power input
- 55.23 kW
- EER, full load (tested)
- 3.00
- COP, full load (tested)
- 3.53
- Rated AEER
- 3.00
- Rated ACOP
- 3.52
- Standby power (PIA)
- 41.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- New Zealand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Temperzone OPA 2110RLTM1FDPQ zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 33,392 | 31,593 |
| Coldresidential | residential | 1.5 | 1.0 | 16,227 | 92,097 |
| Mixedcommercial | commercial | β | β | 43,577 | 17,341 |
| Mixedresidential | residential | 1.5 | 1.0 | 24,813 | 36,650 |
| Hotcommercial | commercial | β | β | 96,724 | 3,703 |
| Hotresidential | residential | 1.5 | 1.0 | 73,292 | 5,837 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 60675 W
- c__t1_half_cap_power_rated
- 37498 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 32855 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 169725 W
- h__h1_half_cap_heat_cap_rated
- 100778 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 30170 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 98772 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 103574 W
Australian GEMS registration details
- Registration number
- AAC7757
- GEMS registration id
- 156345
- Status
- approved, available (self-reported)
- Registration expires
- 3 September 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2020
- Product class
- Class 24
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.