c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
13,416 kWh
4,881 cooling + 8,535 heating
Estimated running cost
$4,293 / year
$358 / month Β· $42,931 over 10 years
Capacity
43.3 kW cooling
44.4 kW heating

134% more electricity than the median of 13 comparable 40 kW reverse cycle ducted packaged registrations (5,740 kWh a year) in the mixed zone. Uses less than 31% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 5% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Temperzone OPA450RLTFPQ running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 24,476$7,832$78,323
Mixed zone 13,416$4,293$42,931
Hot zone 15,748$5,039$50,394

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 43.3 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
APAC P040AHR3SA-LTR40.3 kW heating43 kW cooling4,628 kWh/yr2$1,481
APAC P040AHR3SA-LBB40.3 kW heating43 kW cooling4,628 kWh/yr2$1,481
Actron Air PCG400U39.5 kW heating39.2 kW cooling5,544 kWh/yr1$1,774
Actron Air PCG400R39.5 kW heating39.2 kW cooling5,544 kWh/yr1$1,774
Caa VPA045R3AC49.4 kW heating46.1 kW cooling5,640 kWh/yr1.5$1,805

Air conditioners similar to the Temperzone OPA450RLTFPQ

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
AIRSTAGE RAQ/K/WP/ECO/11843.6 kW heating43.3 kW cooling14,831 kWh/yr1$4,746
AIRSTAGE RAQ/K/WP/* 11843.6 kW heating43.3 kW cooling14,831 kWh/yr1$4,746
APAC P045AHR3SA-RRR44.8 kW heating43.1 kW cooling5,386 kWh/yr1.5$1,724
APAC P045AHR3SA-44.8 kW heating43.1 kW cooling5,386 kWh/yr1.5$1,724
Daikin UAYQ150CY1A43.1 kW heating42.8 kW cooling14,090 kWh/yr1.5$4,509
Daikin UAYN470AFY1A44.1 kW heating45.8 kW cooling15,002 kWh/yr1$4,801

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OPA465RKTBG-P41.1 kW heating43.9 kW cooling5,740 kWh/yr1.5$1,837
Temperzone OPA465RKTB41.3 kW heating42.5 kW cooling6,103 kWh/yr1$1,953

Compare OPA450RLTFPQ with another model

Temperzone OPA450RLTFPQ specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
43.31 kW
Cooling power input
14.49 kW
Rated heating capacity (7 Β°C)
44.43 kW
Heating power input
14.17 kW
EER, full load (tested)
2.99
COP, full load (tested)
3.14
Rated AEER
2.98
Rated ACOP
3.13
Standby power (PIA)
11.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
New Zealand, Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone OPA450RLTFPQ zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6,0727,219
Coldresidential2.01.03,13321,343
Mixedcommercial––8,1543,965
Mixedresidential2.01.04,8818,535
Hotcommercial––18,704839
Hotresidential2.01.014,4231,325
Part-load test points (23 values)
c__t1_min_cap_power_rated
4480 W
h__h2_ext_cap_power_rated
16622 W
c__t1_half_cap_power_rated
6090 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
7490 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
42667 W
h__h1_half_cap_heat_cap_rated
23370 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
3470 W
c__t1_min_cap_cooling_cap_rated
12080 W
c__low_temp_full_cap_power_rated
13243.86 W
c__low_temp_half_cap_power_rated
5030 W
c__t1_half_cap_cooling_cap_rated
19600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
12680 W
c__low_temp_full_cap_cooling_cap_rated
46644.869999999995 W
c__low_temp_half_cap_cooling_cap_rated
21370 W

Australian GEMS registration details

Registration number
AAC6442
GEMS registration id
134619
Status
approved, available (self-reported)
Registration expires
20 February 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 7

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.